44
Unidrive M / Unidrive HS Modular Installation Guide
Issue Number: 5
5.4 Mounting of the control master/
follower/standard pod
For control master/follower pod paralleling connections, refer to Figure
5-9
Figure 5-7 Mounting the control master or standard pod on the
drive
1.
In order to expose the control master/follower mounting holes, the
terminal covers need to be removed. This is done by undoing the
terminal cover screw highlighted and then removing the two plastic
covers.
2. Care must be taken when installing master control pod. Line up the
connector on the back of the master control pod with the respective
connector on the power module. Use the 3 x M5
screws to mount
the control master pod to the drive in the position shown.
The terminal covers can then be re-installed.
Figure 5-8 Mounting the control follower pod on the drive
1.
In order to expose the mounting holes, remove the control follower
pod cover. This is done by undoing the screw highlighted and
removing the cover.
2. Care must be taken when installing follower control pod. Line up the
connector on the back of the follower control pod with the respective
connector on the power module. Use the 3 x M5
screws to mount
the control master pod to the drive in the position shown.
The cover can then be re-installed.
The control master pod can also be remotely mounted and connected to
the first follower with a parallel cable, see Figure 5-19
pod dimensions and remote surface mounting diagram
mounting information.
2
2
1
2
2
1
1
NOTE
Содержание unidrive m
Страница 157: ......
Страница 158: ...0478 0141 05 ...