background image

5

1/4 x 10mm ROUND 
HEAD SCREW (4)

DOWNROD 
EXTENSION

DOWNROD

Figure 2

DOWNROD

SETSCREW (3)

DECORATIVE 
DOWNROD SLEEVE 
ASSEMBLY

Figure 3

DOWNROD

SETSCREW (3)

DOWNROD

UPPER DECORATIVE 
DOWNROD  SLEEVE

DECORATIVE 
STRAP RING

Figure 4

U.L. Model No.: CF3300

5.

Route the motor lead wires and support wire
through the decorative downrod sleeve assembly.
Carefully slide the decorative downrod sleeve
assembly over the downrod and set firmly on
downrod coupling (Figure 3). 

6.

Using the hex wrench (supplied), tighten the three
setscrews located at the top of the decorative
downrod sleeve assembly (Figure 3).

NOTE: It is important that all setscrews are
securely tightened and the decorative downrod
sleeve assembly is secure. To not overtighten
setscrews.

7.

Route the motor lead wires and support wire
through the upper decorative downrod sleeve and
the decorative strap ring (Figure 4). Careful not to
scratch the downrod with the sleeve and ring
during installation.

NOTE: Be careful not to scratch the downrod
during installation.

8.

Position the upper decorative downrod sleeve and
the decorative strap ring just above the decorative
downrod sleeve assembly during initial installation
(Figure 4).

CEILING 
CANOPY 

DOWNROD

MASKING 
TAPE

Figure 5

NOTE: Apply masking tape to the entire edge of
the ceiling canopy center hole to prevent
accidental scratching of downrod surface
(Figure 5).

9.

Route the motor lead wires and support wire
through the ceiling canopy (Figure 5). Use extreme
caution not to scratch the downrod with the ceiling
canopy during installation.

NOTE: Be careful not to scratch the downrod
during installation.

Содержание ST CROIX CF3300AP

Страница 1: ...1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of you...

Страница 2: ... the hardware provided with your fan WARNING Support Directly from Building Structure 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician ...

Страница 3: ...rs 4 One brass barrel nut 5 One brass bushing 6 One ceiling support cable 7 Two 5 32 x 10mm phillips screws n One hardware bag containing 1 Five wire connectors 2 One 1 16 hex wrench 3 One clevis pin 4 One hair pin clip 5 Two threaded studs 6 Two lockwashers 7 Two knurled knobs 8 Two 5 16 18 x 1 4 cup point setscrews 9 One 3 16 hex wrench o One flange assembly bag containing 1 Seventeen 8 32 x 15m...

Страница 4: ... of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod extension to make sure the clevis pin is properly installed 2 While pulling up on the downrod extension securely tighten the two setscrews in the dow...

Страница 5: ...secure To not overtighten setscrews 7 Route the motor lead wires and support wire through the upper decorative downrod sleeve and the decorative strap ring Figure 4 Careful not to scratch the downrod with the sleeve and ring during installation NOTE Be careful not to scratch the downrod during installation 8 Position the upper decorative downrod sleeve and the decorative strap ring just above the ...

Страница 6: ...pported directly from the supporting building structure An electrical box is not acceptable for fan support The building structure must be capable of supporting a load of at least 100 pounds Consult a qualified professional to determine if your installation meets the structural requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To ...

Страница 7: ...2 inches of the threaded part of the mounting screw should be inches secured into a structural wood joist to provide secure mounting 2 Drill a second maximum diameter 1 4 pilot hole up through the center of the electrical box Figure 8 Install the hanger bracket assembly using 3 8 x 5 lag bolt and 3 8 flat washer Route the electrical supply wires through the opening provided on the hanger bracket D...

Страница 8: ...box and the black and blue leads on the other side of the outlet box To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING SMALL BARREL BUSHING FAN CABLE LARGE BRASS BARREL NUT FAN CABLE LARGE BRASS BARR...

Страница 9: ... each blade flange into one of the four large mounting holes on the exterior of each motor hub The flange tip and mounting hole are 8 32 x 15mm FLAT HEAD SCREW 2 per flange blade assembly FLANGE BLADE ASSEMBLY FAN MOTOR ASSEMBLY NOTE Take care not to scratch fan housing when installing blades Figure 12 4 Repeat flange blade assembly instructions for remaining three blades per each fan motor hub as...

Страница 10: ...the decorative strap ring and upper decorative downrod sleeve to the downrod Figure 15 Figure 15 5 Assemble the buckle onto the decorative strap Figure 17 6 Slide the strap back through the buckle as shown in Figure 17 7 Position the buckle on the strap as desired NOTE Do not over tighten the straps the tension should be snug but not over tight 8 Slide the other end of the decorative strap through...

Страница 11: ...on rotate the knob in the clockwise direction to the high position For low speed rotate the knob clockwise to the next position Turn the fans off by fully rotating the knob counter clockwise to the OFF potion Figure 20 To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed ele...

Страница 12: ...esigned to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage The use of any other control not specifically approved for this fan could result in fire shoc...

Страница 13: ...variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupling are not 1 Unscrew screws with hex wrench raise decorative excessively tightened securely downrod sleeve and tighten setscrews securely 2 Setscrew in the hanger ball down...

Страница 14: ... 2 3 4 5 6 7 10 22 13 14 15 21 20 18 12 19 27 DOWNROD KIT SOLD SEPARATELY 26 25 11 8 BLADES SOLD SEPARATELY 25 11 9 BLADES SOLD SEPARATELY 26 31 32 29 30 28 16 17 33 34 35 36 1 25 Repair Parts U L Model No CF3300 ...

Страница 15: ...1 17 5 32 x 10mm Phillips Screw 2 18 Wire Connector 5 19 Threaded Stud 2 20 Lockwasher 2 21 Knurled Knob 2 22 Pin Clevis 1 23 Clip Hairpin 1 24 Hex Wrench 1 25 Screw Flat Head 8 32 x 15mm 17 26 Screw Oval Head 10 32 x 18mm 25 27 Screw Round Head 1 4 x 10mm 9 28 3 16 Hex Wrench 1 29 5 16 18 x 1 4 Cup Point Setscrew 2 30 Support Cable Assembly 1 31 Motor Assembly 763978 763978 32 Hub Rubber 760601 7...

Страница 16: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73850000 Printed in China 08 09 Form No BP7385 U L Model No CF3300 ...

Отзывы: