18
U.L. Model No.: CF4900
8. Wall Control Procedures
(continued)
8.8
Before installing wall control, place wall control in “OFF”
mode by pushing “ON/OFF” switch to the “OFF”
position.
8.9
Connect one black wire of wall control to the “hot” wire.
Securely connect wires with wire connectors supplied
(Figure 29).
8.10
Connect one black wire of wall switch to the “load”
(black) wire in wall box. Securely connect wires with
wire connector supplied.
8.11
Screw wall control into wall box using the supplied
screws. Leave wall control in “OFF” mode until fan
installation is completed.
8.12
The wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the wall
control (Figure 29).
8.13
Install decorator wall plate using the two screws
provided with wall plate. Leave wall control in “OFF”
mode until fan installation is completed (Figure 29).
SW605 FAN/LIGHT
WALL CONTROL
WALL BOX
BLACK
BLK
HOT
SWITCH COVER
DECORATIVE WALL PLATE
SCREWS (2)
NEUTRAL
WIRES
TO
120VA
C SOURCE
TO LOAD
G
R
OU
ND
OFF
ON
Figure 29
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
WARNING
!
SINGLE-POLE INSTALLATION
SW605 FAN/LIGHT
WALL CONTROL
HOT
BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
RECEIVER LOCATED IN THE CEILING COVER
OF THE CEILING FAN
OFF
ON
Figure 28
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
8.6
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan wall control into the outlet box.
8.7
Remove faceplate and screws from existing wall control.
Pull control out from the wall box. Determine the “hot”
wire and the “load” wire and disconnect these wires
from control (Figure 28). Do not attempt to disconnect
any wires not already connected to existing control.