background image

Type S402Y

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a 

business of Emerson Process Management.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or 

guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such 

products at any time without notice.

Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson 

Process Management product remains solely with the purchaser.

©Emerson Process Management Regulator Technologies, Inc., 1992, 2009; All Rights Reserved

Industrial Regulators

Emerson Process Management 

Regulator Technologies, Inc.

USA - Headquarters

McKinney, Texas 75069-1872 USA

Tel: 1-800-558-5853

Outside U.S. 1-972-548-3574

Asia-Pacific

Shanghai, China 201206

Tel: +86 21 2892 9000 
Europe

Bologna, Italy 40013

Tel: +39 051 4190611
Middle East and Africa

Dubai, United Arab Emirates

Tel: +971 4811 8100

Natural Gas Technologies

Emerson Process Management

Regulator Technologies, Inc.

USA - Headquarters

McKinney, Texas 75069-1872 USA

Tel: 1-800-558-5853

Outside U.S. 1-972-548-3574

Asia-Pacific

Singapore, Singapore 128461

Tel: +65 6777 8211
Europe

Bologna, Italy 40013

Tel: +39 051 4190611

Gallardon, France 28320

Tel: +33 (0)2 37 33 47 00

TESCOM

Emerson Process Management

Tescom Corporation

USA - Headquarters

Elk River, Minnesota 55330-2445 USA

Tel: 1-763-241-3238
Europe

Selmsdorf, Germany 23923

Tel: +49 (0) 38823 31 0

For further information visit www.emersonprocess.com/regulators

*Recommended spare part.

Delrin

®

 is a mark owned by E. I. du Pont de Nemours and Co.

Parts list

key  Description 

Part number

  1 

Body, Cast Iron                                                                     

 

  No Gauge Tap

 

    NPS 3/4, NPT 

T80281T0012

 

    NPS 1, NPT 

T80282T0012

 

  Outlet Gauge Tap

 

    NPS 3/4, NPT 

 T13649T0012

 

    NPS 1, NPT  

T13649T0022   

  3 

Spring Case Assembly

 

  For 1 NPT vent                     

T20932T0012

 

  For 3/4 NPT vent  

      T20932T0032

  4  

Screen-Vent, 18-8 Stainless Steel  

T1121338982

  5  

Retaining Ring, Zinc-plated Steel  

T1120925072

  6  

Control spring  

 

  4.5 to 6-inches w.c. (11 to 15 mbar), 302 SST 

 T13539T0012  

 

  5.5 to 8-inches w.c. (14 to 20 mbar), 

 

  

Zinc-plated steel  

T13527T0012

 

  7.5 to 9.5-inches w.c. (19 to 24 mbar), 

 

  Zinc-plated steel 

T13563T0012 

 

  9.5 to 13-inches w.c. (24 to 32 mbar),

 

  Zinc-plated steel 

 T13529T0012

 

  13-inches w.c. to 1.5 psig (0,03 to 0,10 bar), 

 

    302 SST  

T13564T0012

 

  1.5 to 2.5 psig (0,10 to 0,17 bar), Steel 

 T13536T0012

key  Description 

Part number

  7  

Orifice Tube Assembly  

T13651T0012  

 

  1/8-inch       

T13651T0012

 

  3/16-inch     

T13651T0112

 

  1/4-inch      

 T13651T0032

  8*  Orifice Tube, O-Ring, Nitrile (NBR) 

18B3438X012

  9 

Orifice Tube Screw, Steel  

T13526T0012

  10   Diaphragm/Relief Valve Assembly 

 

 

  Relief Valve Spring Color

 

    Blue 

        T20930T0012

 

    Orange 

    T20930T0022

 

    Green   

   T20930T0032

 

    Red     

    T20930T0042

 

  

Brown 

    T20930T0052

  11   Closing Cap, ASA 309, Gray 

 T13524T0062 

  12   Adjusting Screw

 

  4.5 to 6-inches w.c. (11 to 15 mbar), Delrin

®

  

T13523T0012 

    

  5.5 to 8-inches w.c. (14 to 20 mbar), Delrin  

T13523T0012 

   

  7.5 to 9.5-inches w.c. (19 to 24 mbar), Delrin  

T13523T0012 

 

  9.5 to 13-inches w.c. (24 to 32 mbar), Delrin 

 T13523T0012

 

  13-inches w.c. to 1.5 psig (32 mbar to 0,10 bar), 

 

  Zinc  

1B537944012

 

  1.5 to 2.5 psig (0,10 to 0,17 bar), Zinc 

 1B537944012

  13   Machiine Screw, Steel (4 required) 

T13646T0012

  16   Pipe Plug, 304 Stainless Steel 

1E823135042

  22    Screen, 18-8 Stainless steel

          For 3/4 NPT vent     

T13643T0012

          For 1 NPT vent       

 T13644T0012

  23*   Gasket, Neoprene (CR) (not shown) 

  1P753306992

Содержание S402Y

Страница 1: ... procedures for Type S402Y pressure reducing regulators The Type S402Y is typically used in residential or small commercial applications to reduce gas distribution pressures down to a reduced pressure range from 4 5 inches w c to 2 5 psig 11 0 mbar to 0 17 bar The Type S402Y has an integral high capacity internal relief valve Scope of the Manual This instruction manual provides information on inst...

Страница 2: ...c to 1 5 psig 32 mbar to 0 10 bar T13564T0012 Unpainted 0 120 3 05 1 93 49 0 1 5 to 2 5 psig 0 10 to 0 17 bar T13536T0012 Blue 0 120 3 05 2 60 66 0 Table 2 Outlet Pressure Ranges and Control Spring Data orifice size orifice color code wide open Cg for relief sizing Maximum operating pressure for optimum performance 1 Inches mm Psig bar 1 8 3 16 1 4 3 2 4 8 6 4 Blue Green Brown 12 5 28 2 50 0 125 8...

Страница 3: ... matter lodged between the orifice and the valve disk or a failure in the valve disk the regulator diaphragm assembly moves upwards trying to push the valve disk against the orifice The valve disk and disk holder being pressed against the orifice will prevent the cam stem from being able to travel any further upward in conjunction with the diaphragm assembly The continued leakage of the inlet pres...

Страница 4: ...n positions other than vertically down require additional vent protection from the elements Such protection may be with separate hood shields or the Fisher Y602 Series vents 4 Regulator operation within the ratings does not preclude the possibility of damage from the debris in the lines or from external sources A regulator should be inspected for damage periodically and after any overpressure cond...

Страница 5: ...et pressure to prevent damage caused by reverse pressurization of the regulator The steps below apply to the typical installation as indicated 1 Slowly close the upstream shutoff valve 2 Release downstream pressure and be sure the upstream pressure has been exhausted Maintenance Warning To avoid personal injury or equipment damage from sudden release of pressure or uncontrolled gas do not attempt ...

Страница 6: ...mbly by tilting it toward the outlet so that the cam stem may be pulled up and out of the orifice tube assembly key 7 5 Reassemble in the reverse order of the above procedures Place the diaphragm assembly into position in the lower casing being sure the cam stem key 10 is properly inserted into the orifice tube assembly key 7 Note that the diaphragm plate is marked with Inlet and Outlet Install th...

Страница 7: ...Type S402Y 7 T80288 Figure 3 Type S402Y Pressure Reducing Regulator Assembly 3 11 12 6 10 7 8 22 1 9 13 4 5 16 Apply Lub Sealant ...

Страница 8: ...0 2445 USA Tel 1 763 241 3238 Europe Selmsdorf Germany 23923 Tel 49 0 38823 31 0 For further information visit www emersonprocess com regulators Recommended spare part Delrin is a mark owned by E I du Pont de Nemours and Co Parts List Key Description Part Number 1 Body Cast Iron No Gauge Tap NPS 3 4 NPT T80281T0012 NPS 1 NPT T80282T0012 Outlet Gauge Tap NPS 3 4 NPT T13649T0012 NPS 1 NPT T13649T002...

Отзывы: