Specifications and Reference Data
January 2017
Reference Manual
00809-0100-4853, Rev AB
Specifications and Reference Data
68
SmartPower
(17)
1
Adapter for black power module (I.S. power module sold separately)
★
Other options
(include with selected model number)
Extended product warranty
WR3
3-year limited warranty
★
WR5
5-year limited warranty
★
RTD cable (RTD sensor must be ordered separately)
C12
RTD Input with 12-ft. (3,66 m) of shielded cable
★
C13
RTD Input with 24-ft. (7,32 m) of shielded cable
★
C14
RTD Input with 75-ft. (22,86 m) of shielded cable
★
C22
RTD Input with 12-ft. (3,66 m) of armored shielded cable
★
C23
RTD Input with 24-ft. (7,32 m) of armored shielded cable
★
C24
RTD Input with 75-ft. (22,86 m) of armored shielded cable
★
C32
RTD Input with 12-ft. (3,66 m) of ATEX/IECEx Flameproof cable
★
C33
RTD Input with 24-ft. (7,32 m) of ATEX/IECEx Flameproof cable
★
C34
RTD Input with 75-ft. (22,86 m) of ATEX/IECEx Flameproof cable
★
PlantWeb control functionality
A01
F
OUNDATION
Fieldbus advanced control function block suite
★
Mounting brackets
(18)
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
★
B1
Traditional flange bracket, Carbon steel, 2-in. pipe
★
B2
Traditional flange bracket, Carbon steel, panel
★
B3
Traditional flange flat bracket, Carbon steel, 2-in. pipe
★
B7
Traditional flange bracket, B1 with SST bolts
★
B8
Traditional flange bracket, B2 with SST bolts
★
B9
Traditional flange bracket, B3 with SST bolts
★
BA
Traditional flange bracket, B1, all SST
★
BC
Traditional flange bracket, B3, all SST
★
Software configuration
C1
(19)
Custom software configuration (Rosemount 3051SMV
must be completed.)
★
C2
(20)
Custom flow configuration (Rosemount 3051SMV
must be completed for HART devices or
for Fieldbus devices.)
★
NAMUR alarm and saturation levels, high alarm
★
NAMUR alarm and saturation levels, low alarm
★
Custom alarm and saturation signal levels, high alarm
★
Custom alarm and saturation signal levels, low alarm
★
Low alarm (standard Rosemount alarm and saturation levels)
★
Table A-6. Rosemount 3051SMV HART
®
and Fieldbus Ordering Information
The starred offerings (
★
) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Содержание Rosemount MultiVariable 3051SMV
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0100 4853 Rev AB Contents January 2017 Contents ...
Страница 44: ...36 Reference Manual 00809 0100 4853 Rev AB Installation January 2017 Installation ...
Страница 62: ...54 Reference Manual 00809 0100 4853 Rev AB Troubleshooting January 2017 Troubleshooting ...
Страница 98: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 90 ...
Страница 99: ...Product Certifications 91 Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB ...
Страница 101: ...Product Certifications 93 Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB CO S CO O ...
Страница 106: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 98 CO S CO O ...
Страница 108: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 100 CO S CO O ...
Страница 111: ......