Specifications and Reference Data
January 2017
Reference Manual
00809-0100-4853, Rev AB
Specifications and Reference Data
64
A.3 Ordering information
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment.
Table A-6. Rosemount 3051SMV HART
®
and Fieldbus Ordering Information
The starred offerings (
★
) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Model
Transmitter type
3051SMV
Scalable multivariable transmitter
Performance class
(1)
Measurement Types 1 and 2
3
(2)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 15-year limited warranty
★
5
Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 15-year stability
★
Measurement Types 3 and 4
1
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 15-year stability, 15-year limited warranty
★
2
Classic: 0.035% span DP accuracy, 150:1 rangedown, 15-year stability
★
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 15-year limited warranty
★
Multivariable type
M
Measurement with fully compensated mass and energy
(3)
flow calculations
★
P
Measurement of process variables only (no flow calculations)
★
Measurement type
1
Differential pressure, static pressure, and temperature
★
2
Differential pressure and static pressure
★
3
Differential pressure and temperature
★
4
Differential pressure
★
Differential pressure range
(4)
0
(5)
–3 to 3 inH
2
O (–7,46 to 7,46 mbar)
★
1
–25 to 25 inH
2
O (–62,16 to 62,16 mbar)
★
2
–250 to 250 inH
2
O (–621,60 to 621,60 mbar)
★
3
–1000 to 1000 inH
2
O (–2,48 to 2,48 bar)
★
4
–150 to 150 psi (–10,34 to 10,34 bar) for measurement types 1 and 2;
–300 to 300 psi (–20,68 to 20,68 bar) for measurement types 3 and 4
★
5
–2000 to 2000 psi (–137,89 to 137,89 bar)
★
Static pressure type
N
(6)
None
★
A
Absolute
★
G
Gage
★
Static pressure range
Absolute
Gage
N
None
N/A
N/A
★
3
Range 3
0.5 to 800 psia (0,03 to 55,15 bar)
–14.2 to 800 psig (–0,98 to 55,15 bar)
★
4
(7)
Range 4
0.5 to 3626 psia (0,03 to 250,00 bar)
–14.2 to 3626 psig (–0,98 to 250,00 bar)
★
Содержание Rosemount MultiVariable 3051SMV
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0100 4853 Rev AB Contents January 2017 Contents ...
Страница 44: ...36 Reference Manual 00809 0100 4853 Rev AB Installation January 2017 Installation ...
Страница 62: ...54 Reference Manual 00809 0100 4853 Rev AB Troubleshooting January 2017 Troubleshooting ...
Страница 98: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 90 ...
Страница 99: ...Product Certifications 91 Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB ...
Страница 101: ...Product Certifications 93 Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB CO S CO O ...
Страница 106: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 98 CO S CO O ...
Страница 108: ...Product Certifications January 2017 Reference Manual 00809 0100 4853 Rev AB Product Certifications 100 CO S CO O ...
Страница 111: ......