background image

Quick Start Guide

00825-0100-4212, Rev BA

December 2020

Rosemount

 BP20E Power Module for

Wireless Corrosion Transmitter

Содержание Rosemount BP20E

Страница 1: ...Quick Start Guide 00825 0100 4212 Rev BA December 2020 Rosemount BP20E Power Module for Wireless Corrosion Transmitter ...

Страница 2: ...cal access Unauthorized personnel may potentially cause significant damage to and or misconfiguration of end users equipment This could be intentional or unintentional and needs to be protected against Physical security is an important part of any security program and fundamental to protecting your system Restrict physical access by unauthorized personnel to protect end users assets This is true f...

Страница 3: ...Contents Overview 5 Physical installation 6 Verify operation 8 Disposal recycling 9 Product certifications 10 December 2020 Quick Start Guide Quick Start Guide 3 ...

Страница 4: ...Quick Start Guide December 2020 4 Emerson com Rosemount ...

Страница 5: ...Corrosion Transmitters each have a warning printed on them In each case the warning text is the same Below is a figure that shows the label The text of the warning is Use only with approved sensor see instructions Potential static hazard December 2020 Quick Start Guide Quick Start Guide 5 ...

Страница 6: ... Permasense IK220 Installation Kit Hex key 2 5 mm for power module retaining bolts 2 3 Power module installation To install the power module 1 Check power module and sensor terminals are clean and corrosion free 2 Ensure the ring seal around the connector on the power module is present 3 Clip on the power module as shown in Figure 2 1 4 Fit the two M3 retaining bolts using a 2 5 mm AF hex key 5 Th...

Страница 7: ...he opposite side to the sensor label 3 Pull off the power module Note There is a secondary clip mechanism in the electrical connector Some force may be required to remove the power module especially in cold weather 4 Dispose of old power module according to local regulations Refer to the relevant power module datasheet December 2020 Quick Start Guide Quick Start Guide 7 ...

Страница 8: ...rect sensor operation can be verified by Checking the join status in Gateway Manager software OR Checking in Data Manager that data has been received once the sensor has joined the gateway Quick Start Guide December 2020 8 Emerson com Rosemount ...

Страница 9: ... local requirements Please consult current regulations and requirements before shipping 4 3 Handling considerations Each power module contains two D size primary lithium battery Under normal conditions the battery materials are self contained and are not reactive as long as the batteries and the battery pack integrity are maintained Care should be taken to prevent thermal electrical or mechanical ...

Страница 10: ... US National Electrical Code NEC and the Canadian Electrical Code CEC permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions The markings must be suitable for the area classification gas and temperature class This information is clearly defined in the respective codes 5 4 USA Certificate SGSNA 19 BAS 0003 Standards UL 913 8th Edition Revision Dec 6 2013 Marking...

Страница 11: ... hazard and must not be rubbed or cleaned with a dry cloth 5 8 Brazil Safety UL Certificate UL 19 1144X Issue 1 Standards ABNT NBR IEC 60079 0 2013 ABNT NBR IEC 60079 11 2013 Markings Ex ia IIC T4 Ga 50 C Tamb 75 C Specific Condition for Safe Use X See certificate 5 9 China China NEPSI Certificate GYJ20 1347X Standards GB3836 1 2010 GB3836 4 2010 GB3836 20 2010 Markings Ex ia IIC T4 Ga Specific Co...

Страница 12: ...pecific Condition For Safe Use X See certificate for specific conditions of safe use 5 12 India Safety PESO Equipment reference number P451607 1 and P451607 2 Applicable standards EN 60079 0 2018 EN60079 11 2012 IEC 60079 0 2017 IEC 60079 11 2011 Markings Ex ia IIC T4 Specific condition for safe use X See certificate 5 13 Japan I4 CML Intrinsically Safe IS Included on sensor certificates CML 19JPN...

Страница 13: ...Ga 50 C Tamb 75 C Specific condition for safe use X See certificate for specific conditions of safe use 5 14 Declaration of Conformity Figure 5 1 Declaration of Conformity December 2020 Quick Start Guide Quick Start Guide 13 ...

Страница 14: ...5 15 China ROHS Quick Start Guide December 2020 14 Emerson com Rosemount ...

Страница 15: ...December 2020 Quick Start Guide Quick Start Guide 15 ...

Страница 16: ... 6340 Baar Switzerland 41 0 41 768 6111 41 0 41 768 6300 RFQ RMD RCC Emerson com Asia Pacific Regional Office Emerson Automation Solutions 1 Pandan Crescent Singapore 128461 65 6777 8211 65 6777 0947 Enquiries AP Emerson com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P O Box 17033 Jebel Ali Free Zone South 2 Dubai United Arab Emirates 971 4 8118100 971 4 886546...