2.1.7
Flanged style installation
Flanged style installation
Figure 2-6:
C
A
B
A. Installation bolts and nuts (supplied by customer)
B. Gaskets (supplied by customer)
C. Flow direction
Note
The required bolt load for sealing the gasket joint is affected by several factors,
including operating pressure, gasket material, width, and condition. A number of
factors also affect the actual bolt load resulting from a measured torque,
including condition of bolt threads, friction between the nut head and the flange,
and parallelism of the flanges. Due to these application-dependent factors, the
required torque for each application may be different. Follow the guidelines
outlined in ASME PCC-1 for proper bolt tightening. Make sure the flowmeter is
centered between flanges of the same nominal size as the flowmeter.
2.2
Install remote electronics
If you order one of the remote electronics options (options R10, R20, R30, or
RXX), the flowmeter assembly ships in two parts:
1. The meter body with an adapter installed in the support tube and an
interconnecting coaxial cable attached to it.
2. The electronics housing installed on a mounting bracket.
Refer to
Figure 2-7
and these steps to connect the loose end of the coaxial
cable to the electronics housing.
Quick Start Guide
April 2018
8
Rosemount 8600 Series Vortex Flowmeter
Содержание Rosemount 8600D Series
Страница 1: ...Quick Start Guide 00825 0100 4860 Rev EB April 2018 Rosemount 8600 Series Vortex Flowmeter ...
Страница 35: ...April 2018 Quick Start Guide Quick Start Guide 35 ...
Страница 36: ...Quick Start Guide April 2018 36 Rosemount 8600 Series Vortex Flowmeter ...
Страница 37: ...April 2018 Quick Start Guide Quick Start Guide 37 ...
Страница 38: ...Quick Start Guide April 2018 38 Rosemount 8600 Series Vortex Flowmeter ...
Страница 39: ...April 2018 Quick Start Guide Quick Start Guide 39 ...