Reference Manual
00809-0100-4860, Rev BF
Troubleshooting
May 2019
86
Rosemount 8600 Vortex Flow Meter
Note
Use plant approved procedure for removing a temperature sensor from a thermowell.
3.
Remove temperature sensor from electronics by using a 2.5 mm allen wrench to
remove cap head screw from electronics.
4.
Gently pull temperature sensor from electronics.
Note
This will expose the electronics to the atmosphere.
5.
Insert new temperature sensor into electronics housing using care to align pin and
cap head screw to align connector pins.
6.
Tightening cap head screw with 2.5 mm allen wrench.
7.
Slide bolt and ferrule assembly onto temperature sensor and hold into place.
8.
Insert temperature sensor into hole in the top of meter body until it reaches the
bottom of the hole. Hold it in place and tighten bolt with
1
/
2
-in. open end wrench
until
3
/
4
turns past finger tight to seat ferrule.
9.
Put the bracket back on, attach the four bolts, and tighten.
10.
Reapply power to Rosemount 8600D.
5.7
Return of material
To expedite the return process, call the Rosemount North American Response Center at
800-654-RSMT (7768) toll-free number. This center, available 24 hours a day, will assist you
with any needed information or materials.
The center will ask for product model and serial numbers, and will provide a Return Material
Authorization (RMA) number. The center will also ask for the name of the process material
to which the product was last exposed.
Caution
People who handle products exposed to a hazardous substance can avoid injury if they are
informed and understand the hazard. If the product being returned was exposed to a
hazardous substance as defined by OSHA, a copy of the required Material Safety Data Sheet
(MSDS) for each hazardous substance identified must be included with the returned goods.
The Rosemount North American Response Center will detail the additional information and
procedures necessary to return goods exposed to hazardous substances.
Содержание Rosemount 8600 Series
Страница 1: ...Reference Manual 00809 0100 4860 Rev BF May 2019 Rosemount 8600 Series Vortex Flow Meter ...
Страница 2: ......
Страница 8: ...viii Reference Manual 00809 0100 4860 Rev BF Title Page May 2019 Title Page ...
Страница 10: ...Reference Manual 00809 0100 4860 Rev BF Introduction May 2019 2 Rosemount 8600 Vortex Flow Meter ...
Страница 110: ...Reference Manual 00809 0100 4860 Rev BF Specifications and Reference Data May 2019 102 Rosemount 8600 Vortex Flow Meter ...
Страница 112: ...Reference Manual 00809 0100 4860 Rev BF Product Certifications May 2019 104 Rosemount 8600 Vortex Flow Meter ...
Страница 129: ......