Reference Manual
00809-0100-4860, Rev BF
HART
®
Menu Tree
May 2019
118
Rosemount 8600 Vortex Flow Meter
Table D
-
1. Rosemount 8600D HART Menu Tree
1.
Device
Setup
2. PV
3. AO
4. LRV
5. URV
1.
Process
Variables
2.
Diagnostics
and Service
3.
Basic Setup
4.
Detailed
Setup
5. Review
1. PV
2. PV % Range
3. Analog Output
4.
View Other
Variables
1.
Volumetric Flow
2.
Mass Flow
3.
Velocity Flow
4.
Totalizer
5. Pulse Frequency
6. Vortex Frequency
7.
Electronics Temp
8.
Calc Proc Density
9.
Process Temp
-
CJ Temperature
1. Volume Flow
2. Units
3.
Special Units
1. Base Volume Unit
2. Base Time Unit
3. User Defined Unit
4. Conversion Number
1. Mass Flow
2. Mass Flow Unit
1. Total
2. Start
3. Stop
4. Reset
5. Totalizer Config
1. Electr Temp
2. Elec Temp Units
1.
Test/Status
2. Loop Test
3. Pulse Output Test
4.
Flow Simulation
5. D/A Trim
6. Scaled D/A Trim
7. Shed Freq at URV
1. View Status
2. Config Status
3. Density Test Calc
4.
Min/Max Temps
5. Self Test
6. Reset Xmtr
1. PV
2. Shedding Frequency
3. Configure Flow Simulation
4. Enable Normal Flow
5. Mode
1. Tag
2.
Process Config
3. Reference K Factor
4. Flange Type
5. Mating Pipe ID
6.
Variable Mapping
7. PV Unit
8.
Range Values
9. PV Damping
- Auto Adjust Filter
1. Transmitter Mode
2. Process Fluid
3. Fixed Process Temp
4.
Density / Dens Ratio
1.
Density Ratio
2. Fixed Process
Density
1. Density Ratio
2.
Calc Density Ratio
1. PV is
2. SV is
3. TV is
4. QV is
1. URV
2. LRV
3. PV Min Span
4. USL
5. LSL
1. Operating Conditions
2. Base Conditions
3. Exit
1.
Characterize Meter
2.
Configure Outputs
3.
Signal Processing
4.
Device Information
1.
K Factor
2. Mating Pipe ID
3. Flange Type
4. Wetted Material
5. Meter Body #
6. Installation Effects
1. Reference K Factor
2. Compensated K Factor
1.
Anlg Output
2.
Pulse Output
3.
HART Output
4. Local Display
1.
Range Values
2. Loop Test
3. Alarm Jumper
4. D/A Trim
5. Alarm Level Select
6.
Alarm/Sat Levels
7. Scaled D/A Trim
8. Recall Factory Trim
1. Vel. Flow
2. Vel. Flow Unit
3. Velocity Meas Base
1. High Alarm
2. High Saturation
3. Low Saturation
4. Low Alarm
1.
Pulse Output
2. Pulse Output Test
1. Off
2. Direct (Shedding)
3. Scaled Volume
4. Scaled Velocity
5. Scaled Mass
1. Poll Address
2. # of Req Preams
3. Num Resp Preams
4. Burst Mode
5. Burst Option
6.
Burst Xmtr Vars
1.Xmtr Var, Slot 1
2.Xmtr Var, Slot 2
3.Xmtr Var, Slot 3
4.Xmtr Var, Slot 4
1.
Optimize Flow Range
2.
Manual Filter Adjust
3. Filter Restore
4.
Damping
5. LFC Response
1. Manufacturer
2. Tag
3. Descriptor
4. Message
5. Date
6. Write Protect
8.
Revision Numbers
7.
Transmitter Options
1. PV
2. LFC
3. Sig/Tr
4. Auto Adjust
Filter
1. PV
2. Sig/Tr
3. Low Flow Cutoff
4. Low Pass Filter
5. Trigger Level
1. Universal Rev
2. Transmitter Rev
3. Software Rev
4. Hardware Rev
5. Final Assembly #
6. Device ID
7. Board Serial #
1. Proc
Density
2. Density
Units
1. Proc Temp
2. Proc Temp
Units
3. T/C Failure
Mode
1. URV
2. LRV
3. PV Min Span
4. USL
5. LSL
1. CJ Temp
2. CJ Temp Units
1. Min Electr Temp
2. Max Electr Temp
1. PV Damping
2. Flow Damping
3. Temperature Damping
Содержание Rosemount 8600 Series
Страница 1: ...Reference Manual 00809 0100 4860 Rev BF May 2019 Rosemount 8600 Series Vortex Flow Meter ...
Страница 2: ......
Страница 8: ...viii Reference Manual 00809 0100 4860 Rev BF Title Page May 2019 Title Page ...
Страница 10: ...Reference Manual 00809 0100 4860 Rev BF Introduction May 2019 2 Rosemount 8600 Vortex Flow Meter ...
Страница 110: ...Reference Manual 00809 0100 4860 Rev BF Specifications and Reference Data May 2019 102 Rosemount 8600 Vortex Flow Meter ...
Страница 112: ...Reference Manual 00809 0100 4860 Rev BF Product Certifications May 2019 104 Rosemount 8600 Vortex Flow Meter ...
Страница 129: ......