115
Rosemount 8600 Vortex Flow Meter
Reference Manual
May 2019
Electronics Verification
00809-0100-4860, Rev BF
Example 2 (SI units)
Therefore, an input frequency of 650.00 Hz represents a flow rate of 3446.4 kg/hr in this
application.
For a given input frequency, you may also determine the current output. Use the prior
example with an input frequency of 275 Hz:
URV= 3600 kg/hr
LRV= 0 kg/hr
F
in
(Hz) = 275
= 10.48 mA
Therefore, an input frequency of 275.00 Hz represents an output current of 10.48 mA.
Fluid
= Saturated Steam
URV
= 3600 kg/hr
Line size
= 80 mm.
LRV
= 0 kg/hr
Line pressure
= 700 kPas
C
16
= C
11
/
Operating
Temperature
= 170 °F
Density(
)
= 4.169 kg/cu-mtr
(operating)
Viscosity
= 0.015 cp
Input
Frequency
= 650 Hz
K-factor
(compensated)
= 10.715 (via Field Communicator or AMS)
M
= F(Hz) /(K x C
16
)
= 650/{10.715 x (C
11
/
= 650/{10.715 x (0.0733811/4.169
= 650/(10.715 x 0.017602
= 3446.4 kg/hr
I
F Hz
K C
16
LRV
–
URV LRV
–
-----------------------------------------------------------
16
4
+
=
I
275
10.715 0.017602
0
–
3600 0
–
----------------------------------------------------------------------------------
16
4
+
=
Содержание Rosemount 8600 Series
Страница 1: ...Reference Manual 00809 0100 4860 Rev BF May 2019 Rosemount 8600 Series Vortex Flow Meter ...
Страница 2: ......
Страница 8: ...viii Reference Manual 00809 0100 4860 Rev BF Title Page May 2019 Title Page ...
Страница 10: ...Reference Manual 00809 0100 4860 Rev BF Introduction May 2019 2 Rosemount 8600 Vortex Flow Meter ...
Страница 110: ...Reference Manual 00809 0100 4860 Rev BF Specifications and Reference Data May 2019 102 Rosemount 8600 Vortex Flow Meter ...
Страница 112: ...Reference Manual 00809 0100 4860 Rev BF Product Certifications May 2019 104 Rosemount 8600 Vortex Flow Meter ...
Страница 129: ......