118
Reference Manual
00809-0200-4728, Rev RA
Appendix A: Specifications and Reference Data
April 2015
Specifications and Reference Data
External ground screw assembly
The external ground screw assembly can be ordered by specifying code G1 when an enclosure is
specified. However, some approvals include the ground screw assembly in the transmitter
shipment, hence it is not necessary to order code G1. The table below identifies which approval
options include the external ground screw assembly and which do not.
Custom configuration
Custom configurations are to be specified when ordering. This configuration must be the same
for all sensors. The following table lists the necessary requirements to specify a custom
configuration.
Option code
External ground screw
assembly included?
E5, I1, I2, I5, I6, I7, K5, K6, NA, I3, KB
No–Order option code G1
E1, E2, E3, E4, E7, K7, N1, N7, ND, K1, K2, KA, NK, N3, KD, T1
Yes
Option code
Customization available
HART
C1
: Factory Configuration Data (CDS
required)
Also needs option code:
...DC
...DC
...M4 or M5
Date
: day/month/year
Descriptor
: 8 alphanumeric characters
Message
: 32 alphanumeric characters
Hardware Tag
: 13 Characters
Software Tag
: 8 Characters
Sensor Type and Connection
Measurement Range and Units
Damping Value
Failure Mode:
High or Low
Hot Backup:
Mode and PV
Sensor Drift Alert:
Mode, Limit and Units
Display Configuration
: Choose what will be shown on the LCD display
Custom Alarm and saturation levels
: Choose custom High and Low Alarm
and Saturation levels
Security information:
Write Protection, HART Lock and Local Operator
Interface Password
C2
:Transmitter – Sensor Matching
The transmitters are designed to accept Callendar-Van Dusen constants from
a calibrated RTD. Using these constants, the transmitter generates a custom
curve to match the sensor-specific curve. Specify a Series 65, 65, or 78 RTD
sensor on the order with a special characterization curve (V or X8Q4 option).
These constants will be programmed into the transmitter with this option.
A1, CN, or C8
: Alarm Level
Configuration
A1:
NAMUR Alarm and Saturation Levels, with High Alarm configured
CN:
NAMUR Alarm and Saturation Levels, with Low Alarm configured
C8:
Low Alarm (Standard Rosemount Alarm and Saturation Values)
Q4
: Three-Point Calibration with
Certificate
Calibration certificate. Three-Point calibration at 0, 50 and 100% with
certificate.
C4
: Five-Point Calibration
Will include five-point calibration at 0, 25, 50, 75, and 100% analog and
digital output points. Use with Calibration Certificate Q4
HR7
: HART Revision configuration
Your 644 Head mount and Field Mount devices are HART revision selectable.
Order the HR7 code to configure your device to operate in HART Revision 7
mode. Your device is also configurable in the field. Refer to the 644 Quick
Start Guide or Reference Manual for more instructions.
Long Software Tag:
32 Characters
Содержание Rosemount 644
Страница 2: ......
Страница 4: ...iv Reference Manual 00809 0200 4728 Rev RA Title Page April 2015 ...
Страница 10: ...x Reference Manual 00809 0200 4728 Rev RA Table of Contents April 2015 Table of Contents ...
Страница 150: ...140 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 151: ...141 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 154: ...144 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 156: ...146 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 160: ...150 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 161: ...151 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 162: ...152 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 163: ...153 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 164: ...154 Reference Manual 00809 0200 4728 Rev RA Appendix B Product Certifications April 2015 Product Certifications ...
Страница 180: ...Index 2 Reference Manual 00809 0200 4728 Rev RA Index April 2015 Index ...
Страница 181: ......