Note
Take protective measures, such as fitting an angled shield (reverse-V shape)
to the silo or selecting an extension tube option, when there are high
mechanical forces.
2.1.3
Mounting location
Take time to assess a suitable mounting location. Avoid mounting the level
switch near the filling point, internal structures, and walls of a silo (or other
vessel). When mounting the extended length versions of the level switch, it
is especially important to consider internal structures. Forcing the level
switch into a small or congested space risks damage to the sensor and could
impair the protection it provides.
2.1.4
Sliding sleeve
Tighten both M8 screws with a torque of 20 Nm to establish a seal and
maintain the process pressure. See
Figure 2-2: Sliding Sleeve, M8 Screws
A
A. Two off M8 screws
2.1.5
Flange mounting
A suitable gasket must be fitted to provide a seal when the flanges are
tightened.
2.1.6
Hygienic applications
The food-grade materials are suitable for use under normal and predictable
hygienic applications (according to directive 1935/2004 Art.3). There are
currently no hygienic certifications for the Rosemount 2501.
2.1.7
Rotatable housing
The housing of the level switch can be rotated against the threaded
connection after mounting.
October 2019
Quick Start Guide
Quick Start Guide
13