![Emerson Rosemount 1154DH Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/emerson/rosemount-1154dh/rosemount-1154dh_reference-manual_103580048.webp)
Reference Manual
00809-0100-4631, Rev BA
April 2007
Rosemount 1154 Series H
6-6
Rosemount 1154HH:
0.5 psia to 3,000 psig (3.4 kPa abs to 20.7 MPa) maximum rated static
pressure for operation within specifications; overpressure limit is 3,000
psig (20.7 MPa) on either side without damage to the transmitter
Overpressure Limits
Rosemount 1154SH:
Operates within specification from 0.5 psia (3.4 kPa abs) to upper range
limit; overpressure limit is 4,500 psig (31.0 MPa) for Range Code 9,
without damage to the transmitter
PHYSICAL
SPECIFICATIONS
Materials of Construction
Isolating Diaphragms:
316L SST
Drain/Vent Valves:
316 SST
Process Flanges:
CF-8M (cast version of 316 SST)
O-rings:
316L SST
Electronics Housing O-rings:
Ethylene propylene
Fill Fluid:
Silicone oil
Flange Bolts:
Plated alloy steel, per ASTM A-540
Electronics Housing:
316 SST
Module Shroud:
304L SST
Module Shroud Potting:
Silicone RTV
Mounting Bracket:
316L SST
Mounting Bolts:
SAE J429 Carbon steel, Grade 2 or Grade 5
Weight
26.6 lb (12.1 kg) including mounting bracket
Electrical Connections
1
/
2
–14 NPT conduit with screw terminals
Process Connections
3
/
8
in. Swagelok compression fitting, 316 SST (¼–18 NPT optional)
Содержание Rosemount 1154DH
Страница 6: ...Reference Manual 00809 0100 4631 Rev BA April 2007 Rosemount 1154 Series H 1 2 ...
Страница 10: ...Reference Manual 00809 0100 4631 Rev BA April 2007 Rosemount 1154 Series H TOC 4 ...
Страница 12: ...Reference Manual 00809 0100 4631 Rev BA April 2007 Rosemount 1154 Series H 1 2 ...
Страница 52: ...Reference Manual 00809 0100 4631 Rev BA April 2007 Rosemount 1154 Series H 6 10 ...
Страница 55: ......