7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF905-1
FAN MOTOR
ASSEMBLY
OUTLET
BOX
FAN MOTOR
ASSEMBLY
WHITE WIRE
WIRE
CONNECTOR
SUPPLY WHITE WIRE
4.4
Connect the Fan Motor Assembly White Wire to the
Supply White (neutral) Wire using a supplied 12 ga.
Wire Connector (Figure 5).
4. How to Wire Your Ceiling Fan
(Continued)
Figure 5
FAN MOTOR
ASSEMBLY
FAN MOTOR
ASSEMBLY
BLACK WIRE
WIRE
CONNECTOR
SUPPLY BLACK WIRE
WIRE
CONNECTOR
FAN MOTOR ASSEMBLY
BLUE WIRE
4.5
Securely connect the Fan Motor Assembly Black
Wire to the Supply Black (hot) Wire using 12 ga. Wire
Connector supplied (Figure 6).
Cap the Fan Motor Assembly Blue Wire with a 12 ga.
Wire Connector (supplied) if using the supplied Wall
Control (Figure 6).
NOTE: If you are using an Emerson Light Fixture
with your fan, see the Light Fixture Owner’s Manual
for wiring.
Figure 6
FAN MOTOR
ASSEMBLY
OUTLET
BOX
4.6
After connections have been made, turn Wires upward
and carefully push the Wires into the Outlet Box, with
the White and Green Wires on one side of the Outlet
Box and the Black and Blue Wires on the other side of
the Outlet Box.
Figure 7
To avoid risk of fire or shock, check to see that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except for
the ground wire. Do not operate fan until blades are in
place. Noise and fan damage could result.
WARNING
!