background image

7

UPPER
STYROFOAM
SECTION

FAN MOTOR AND
HOUSING ASSEMBLY

Figure 12

18. Position one fan blade on the flange assembly and

secure by installing the left and right blade holder
caps using two 10-32 x 3/8” pan head screws (sup-
plied) for each holder cap (Figure 13). Install the
remaining four fan blades using the same procedure.

19. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box. (Figure 15.)

20. Carefully lift the fan and seat the hanger

ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 16). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 15).

LEFT BLADE
HOLDER CAP

FLANGE
ASSEMBLY

10-32 X 3/8"
PAN HEAD SCREW
(2 PER HOLDER CAP)

RIGHT BLADE
HOLDER CAP

Figure 13

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 15

CEILING

FLOOR

AT LEAST

7'

Figure 14

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 16

21. Position the receiver (supplied with the SR330

Remote Control or SW350 Wall Control) by
passing the opening in the receiver over the
downrod (Figure 17).

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 14).

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.

WARNING

!

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

WARNING

!

Содержание ODYSSEY CF2454BQ02

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model No CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02 THE ODYSSEY Series Ceiling Fan Owner s Manual Part No F40BP72110008 Form No BP7211 8 Net Weight 26 0 Lbs ...

Страница 2: ...rician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt ...

Страница 3: ...of the wire size to right 3 Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted BLADE HOLDER CAPS LEFT BLADE HOLDER CAP...

Страница 4: ...L DOWNROD CLEVIS PIN SETSCREW Figure 2 4 DOWNROD CUT HERE 3 UPLIGHT YELLOW LEAD ASSEMBLY WIRING HARNESS BLUE WIRE Figure 3 IF THE CF2454 CEILING FAN IS BEING INSTALLED WITH ANY OTHER CONTROL METHOD SKIP SECTION A AND GO TO SECTION B TO BEGIN ASSEMBLY INSTRUCTIONS Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this ti...

Страница 5: ...ng All wires and wire connectors should be placed through the motor coupling slot beneath the down rod See Figure 5 7 Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip The clevis pin must go through the holes in the motor coupling and the holes in the downrod Figure 5 Push the straight leg of the hairpin clip thro...

Страница 6: ...e downrod and slide the hanger ball up the downrod aligning the ball so the pin is cap tured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Position the center styrofoam section on the upper section and then position the fan motor and housing on the center sec...

Страница 7: ...ntrol by passing the opening in the receiver over the downrod Figure 17 The fan must be hung with at least 7 of clearance from floor to blades Figure 14 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable...

Страница 8: ...assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 18 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 9 4 Push the uplight yellow lead assembly connector through the downrod Figure 19 until it extends about 4 5 Cut the yellow lead approximately 3 f...

Страница 9: ...inst the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 13 The blue black yellow and white leads exiting the downrod are 80 inches long Before installing fan measure up approximately 6 to 9 inches above the ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads NOTE If you are installing your fan with a SR3...

Страница 10: ...lips head screws supplied into the threaded holes in the adapter assembly Figure 27 NOTE Do not pinch wires between the light kit plate assembly and the adapter assembly 19 Lift the fan assembly from the styrofoam and remove the center styrofoam section Turn the fan assembly over and carefully position it on the upper styrofoam section so that the hanger ball downrod assembly is at the top Figure ...

Страница 11: ...lack wire from the downrod to the supply black hot wire using wire connector supplied c Cut terminal off of the yellow lead wire and strip insulation 1 2 from end of wire d Securely connect the blue wire and yellow wire from the downrod to the supply red hot wire using wire connector supplied After connec tions have been made turn leads upward and carefully push leads into the outlet box with the ...

Страница 12: ...BOX LIGHT CONTROL GREEN WIRE GROUND FROM HANGER BRACKET TO 120 VOLT SUPPLY WHITE WHITE GROUND GROUND GREEN WIRE GROUND FROM HANGER BALL LISTED WIRE CONNECTOR 4 GROUND WIRE WHT RED BLACK EMERSON FAN CONTROL BLACK HOT YELLOW BLUE RED FINAL ASSEMBLY 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket 2 Lift the ceiling cover up to the threaded studs and turn unti...

Страница 13: ... operating 2 Screws holding blades to flange assemblies 2 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew excessively securely 2 Setscrew in hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball is loose downrod assembly 3 Hanger bracket and or ceiling outlet box is not 3 Tighten the hanger bracket scre...

Страница 14: ...14 20 12 13 14 4 2 1 3 5 6 7 9 10 17 16 24 21 3 8 11 19 22 26 25 23 8 18 17 15 15 7 27 Repair Parts ...

Страница 15: ...802 6 21 Light Kit Plate Assembly 761810 761810 761810 761810 22 Light Kit Glass 761745 761745 761745 761745 23 Die Cast Glass Holder 761864 3 761864 761864 5 761864 6 26 Uplight Lead Assembly 761790 761790 761790 761790 Loose Parts Bag containing 761798 2 761798 761798 1 761798 1 3 Threaded Stud 8 32 x 1 1 4 4 5 Wire Connector 7 6 Setscrew Wrench 5 32 7 Lockwasher 4 8 Knurled Knob 4 11 Clip Hairp...

Страница 16: ...e responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover a...

Отзывы: