background image

5. Obtain the die cast glass holders and light kit glass

from the protective bag.

6. Position light kit glass carefully on a convenient

surface with the open side face down.

7. Remove the protective cover from the adhesive

backed material on the glass holders (Figure 35).

8. Firmly press the die cast glass holders into position

on the light kit glass (Figure 36).

9.

Repeat these procedures for the second die cast
holder.

10. Carefully turn the light kit glass assembly over

and thread the two screws (supplied) into the die
cast glass holder. Leave approximately 3/16” of
the thread revealed (Figure 37).

11. Raise the light kit glass assembly and insert the

two screws in the two keyholes in the light kit
adapter. Turn the light kit glass assembly
counterclockwise to engage the screws in the
slots; tighten the screws using a 6-inch blade
screwdriver or a 90-degree angled
screwdriver (Figure 38). 

DIE CAST
GLASS HOLDER

PROTECTIVE 
COVER ON
ADHESIVE 
BACKED 
MATERIAL

Figure 35

DIE CAST
GLASS HOLDER

LIGHT KIT
GLASS 

Figure 36

INSERT SCREW (SUPPLIED) 
WITH APPROXIMATELY 3/16" 
GAP BETWEEN SCREW HEAD 
AND DIE CAST GLASS 
HOLDER

DIE CAST
GLASS HOLDER

LIGHT KIT GLASS 
ASSEMBLY

Figure 37

BLACK

BLACK FAN WIRE

LISTED OUTLET BOX

LIGHT
CONTROL

GREEN WIRE
(GROUND) 
FROM 
HANGER 
BRACKET

TO 120 
VOLT
SUPPLY

WHITE

WHITE

GROUND

GROUND

GREEN WIRE (GROUND)
FROM  HANGER BALL

LISTED WIRE
CONNECTOR (4)

GROUND
WIRE

WHT.

RED

BLACK

EMERSON
FAN
CONTROL

BLACK
(HOT)

YELLOW

BLUE

RED

FINAL ASSEMBLY

1. Screw the two 1-1/4” threaded studs (supplied) into

the tapped holes in the hanger bracket.

2. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 34).

3. Secure the ceiling cover in place by installing two

lockwashers and two knurled knobs (supplied)
(Figure 34). Tighten the knurled knobs securely
until the ceiling cover fits snugly against the ceiling
and the hole in the ceiling cover is clear of the
downrod. 

4. Screw in three 40-watt (maximum) candelabra

base lamps in the uplight assembly sockets and
three 60-watt (maximum) candelabra base lamps in
the light kit plate sockets for the lower light.

12

1-1/4"
THREADED
STUD

CEILING COVER

KNURLED KNOB

LOCKWASHER

Figure 34

Figure 33

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

Содержание ODYSSEY CF2454BQ02

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model No CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02 THE ODYSSEY Series Ceiling Fan Owner s Manual Part No F40BP72110008 Form No BP7211 8 Net Weight 26 0 Lbs ...

Страница 2: ...rician 3 The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt ...

Страница 3: ...of the wire size to right 3 Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted BLADE HOLDER CAPS LEFT BLADE HOLDER CAP...

Страница 4: ...L DOWNROD CLEVIS PIN SETSCREW Figure 2 4 DOWNROD CUT HERE 3 UPLIGHT YELLOW LEAD ASSEMBLY WIRING HARNESS BLUE WIRE Figure 3 IF THE CF2454 CEILING FAN IS BEING INSTALLED WITH ANY OTHER CONTROL METHOD SKIP SECTION A AND GO TO SECTION B TO BEGIN ASSEMBLY INSTRUCTIONS Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this ti...

Страница 5: ...ng All wires and wire connectors should be placed through the motor coupling slot beneath the down rod See Figure 5 7 Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip The clevis pin must go through the holes in the motor coupling and the holes in the downrod Figure 5 Push the straight leg of the hairpin clip thro...

Страница 6: ...e downrod and slide the hanger ball up the downrod aligning the ball so the pin is cap tured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Position the center styrofoam section on the upper section and then position the fan motor and housing on the center sec...

Страница 7: ...ntrol by passing the opening in the receiver over the downrod Figure 17 The fan must be hung with at least 7 of clearance from floor to blades Figure 14 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable...

Страница 8: ...assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 18 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 9 4 Push the uplight yellow lead assembly connector through the downrod Figure 19 until it extends about 4 5 Cut the yellow lead approximately 3 f...

Страница 9: ...inst the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 13 The blue black yellow and white leads exiting the downrod are 80 inches long Before installing fan measure up approximately 6 to 9 inches above the ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads NOTE If you are installing your fan with a SR3...

Страница 10: ...lips head screws supplied into the threaded holes in the adapter assembly Figure 27 NOTE Do not pinch wires between the light kit plate assembly and the adapter assembly 19 Lift the fan assembly from the styrofoam and remove the center styrofoam section Turn the fan assembly over and carefully position it on the upper styrofoam section so that the hanger ball downrod assembly is at the top Figure ...

Страница 11: ...lack wire from the downrod to the supply black hot wire using wire connector supplied c Cut terminal off of the yellow lead wire and strip insulation 1 2 from end of wire d Securely connect the blue wire and yellow wire from the downrod to the supply red hot wire using wire connector supplied After connec tions have been made turn leads upward and carefully push leads into the outlet box with the ...

Страница 12: ...BOX LIGHT CONTROL GREEN WIRE GROUND FROM HANGER BRACKET TO 120 VOLT SUPPLY WHITE WHITE GROUND GROUND GREEN WIRE GROUND FROM HANGER BALL LISTED WIRE CONNECTOR 4 GROUND WIRE WHT RED BLACK EMERSON FAN CONTROL BLACK HOT YELLOW BLUE RED FINAL ASSEMBLY 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket 2 Lift the ceiling cover up to the threaded studs and turn unti...

Страница 13: ... operating 2 Screws holding blades to flange assemblies 2 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew excessively securely 2 Setscrew in hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball is loose downrod assembly 3 Hanger bracket and or ceiling outlet box is not 3 Tighten the hanger bracket scre...

Страница 14: ...14 20 12 13 14 4 2 1 3 5 6 7 9 10 17 16 24 21 3 8 11 19 22 26 25 23 8 18 17 15 15 7 27 Repair Parts ...

Страница 15: ...802 6 21 Light Kit Plate Assembly 761810 761810 761810 761810 22 Light Kit Glass 761745 761745 761745 761745 23 Die Cast Glass Holder 761864 3 761864 761864 5 761864 6 26 Uplight Lead Assembly 761790 761790 761790 761790 Loose Parts Bag containing 761798 2 761798 761798 1 761798 1 3 Threaded Stud 8 32 x 1 1 4 4 5 Wire Connector 7 6 Setscrew Wrench 5 32 7 Lockwasher 4 8 Knurled Knob 4 11 Clip Hairp...

Страница 16: ...e responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover a...

Отзывы: