10
ProLink
®
II Software for Micro Motion
®
Transmitters
Installation and Setup
Table 2-1
Transmitter terminals for ProLink II connections
Transmitter
Terminals for connection type
HART/Bell 202
HART/RS-485
Modbus/RS-485
Service port
PV+
PV–
A
B
A
B
A
B
IFT9701/9703
4–20+
4–20–
RFR9712
17
16
21
22
RFT9739
• Rack-mount
Z30
D30
Z22
D22
Z22
D22
• Field-mount
17
18
27
26
27
26
Model 1700/2700 with
analog outputs
1
2
5
6
5
6
8
7
LF-Series field-mount
with output code 1 or 3
1
2
5
6
5
6
8
7
Model 1700/2700 with
I.S. outputs
(1)
1
2
8
7
Model 2700 with
configurable I/O
1
2
8
7
LF-Series field-mount
with output code 4
1
2
8
7
Model 2700 with
F
OUNDATION
™
fieldbus
8
7
LF-Series field-mount
with output code 6
8
7
Model 2700 with
PROFIBUS-PA
8
7
Model 2200S
HART clips
Model 2400S with
analog outputs
1
2
Service port clips
or
HART clips
Model 2400S with
DeviceNet
Service port clips
Model 2400S with
PROFIBUS-DP
Service port clips
Series 3000
• Panel-mount with
solder-tail or screw
connectors
c2
a2
c32
a32
c32
a32
c32
a32
• Panel-mount with
I/O cables
14
15
24
25
24
25
24
25
• Rack-mount
c2
a2
c32
a32
c32
a32
c32
a32
• Field-mount
2
1
11
12
11
12
11
12
Model 1500/2500
21
22
33
34
33
34
LF-Series DIN rail with
output code 2, 5, or 8
21
22
33
34
33
34
Model 7826/7828
(2)
3
4
Model 7829
(2)
3
4
Model 7835, 7845,
7846, or 7847
(2)
11
12
Содержание Network Router
Страница 6: ...iv ProLink II Software for Micro Motion Transmitters ...
Страница 12: ...6 ProLink II Software for Micro Motion Transmitters ...
Страница 42: ...36 ProLink II Software for Micro Motion Transmitters ...
Страница 64: ...58 ProLink II Software for Micro Motion Transmitters ...
Страница 66: ...60 ProLink II Software for Micro Motion Transmitters ...
Страница 70: ...64 ProLink II Software for Micro Motion Transmitters ...
Страница 78: ...72 ProLink II Software for Micro Motion Transmitters ...
Страница 94: ...88 ProLink II Software for Micro Motion Transmitters ...
Страница 95: ......