11. Cause and remedy of operating faults

If the valve function or operating action is faulty, a check should be made to ensure that the 
assembly and installation work has been carried out and completed in accordance with the 
installation and maintenance instructions.
The information relating to material, pressure, temperature and direction of flow should be 
compared with the installation diagram of the pipeline system. Furthermore, a check should be 
made on whether the installation conditions correspond to the technical data given in the data 
sheet or on the rating plate.

The safety regulations must always be observed when troubleshooting.
Repair work must only be carried out by the manufacturer’s trained personnel.

12. Decommissioning

Removal of the valve for repair or servicing is often carried out carelessly, as the valve has to be 
repaired or replaced in any case. However, it is recommended that the valve is removed with 
care, without damaging the PTFE, so that the possible cause of damage can be determined after 
removal.

Attention! Check that the pipe is depressurized and drained.
With corrosive, inflammable, aggressive or toxic media, ventilate the pipeline system.

-  Only allow assembly work to be carried out by qualified personnel (see Section 2.3)
-  Almost fully close the valve (note position of the flat sections of the control shaft)
-  Loosen all flange bolts and withdraw them until the valve can be removed
-  Spread the flanges apart using a suitable tool and withdraw the valve

13. Spare parts

Always provide the information in accordance with the rating plate fitted on the mounting flange 
when ordering seals and other spare parts.

15. Customer service

For further information or technical advice please contact:

Neotecha AG

Etzelstrasse 37-39
CH-8634 Hombrechtikon / Switzerland
Telephone  : +41 (0) 55 - 254 41 41
Fax 

: +41 (0) 55 - 254 41 00

16. Validity of the Installation and Maintenance Instructions

These installation and maintenance instructions are valid from 01.09.2001 until the next revision.

14. Disposal

Hand in the correctly cleaned valve to the scrap material recycling plant.

Badly cleaned valves can cause severe burning of the hands
and other parts of the body.

If the valve is passed on to a third party, the manufacturer no longer guarantees the valve.

Содержание NEOTECHA SNB Series

Страница 1: ...tional regulations are complied with The manufacturer reserves all rights to make technical changes and improvements at any time The use of these installation and maintenance instructions assumes that the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 Safety Please also read through these notes caref...

Страница 2: ...emperature of the valve can be up to a maximum of 200 C Suitable precautions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 3 5 Usage Restrictions Before the valve is installed a check shou...

Страница 3: ... a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve body material is cast onto the valve 3 8 Handling prior to installation on versions with protective covers only remove these immediately prior to installation protect against the effects of weather e g dampness...

Страница 4: ... various intermediate positions version Z In addition the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6...

Страница 5: ...ening torques for SNB SNC ball valves DIN PN16 and JIS 10K Recommended torques DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for SNB SNC ball valves ANSI B 16 10 class 150 lbs 6 8 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the valve spread the mounting flanges apart sufficiently using a suitable...

Страница 6: ...lves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an SNC series C valve should be used This type can also be fitted with various control orifice plates Refer to the flow characteristic d...

Страница 7: ...so that the possible cause of damage can be determined after removal Attention Check that the pipe is depressurized and drained With corrosive inflammable aggressive or toxic media ventilate the pipeline system Only allow assembly work to be carried out by qualified personnel see Section 2 3 Almost fully close the valve note position of the flat sections of the control shaft Loosen all flange bolt...

Отзывы: