manualshive.com logo in svg
background image

15 

1/2” 

95 

65 

4 x 14

20 

3/4” 

105 

75 

4 x 14

25 

1” 

115 

85 

4 x 14

40 

1 1/2” 

150 

110 

4 x 18

50 

2” 

165 

125 

4 x 18

65 

2 1/2” 

185 

145 

4 x 18

80 

3” 

200 

160 

8 x 18

100 

4” 

220 

180 

8 x 18

150* 

6” 

279 

241 

8 x 22

15 

1/2” 

89 

60.3 

4 x 16

20 

3/4” 

98 

70.0 

4 x 16

25 

1” 

108 

79.5 

4 x 16

40 

1 1/2” 

127 

98.5 

4 x 16

50 

2” 

152 

120.5 

4 x 19

65 

2 1/2” 

185 

145.0 

4 x 19

80 

3” 

190 

152.5 

4 x 19

100 

4” 

229 

190.5 

8 x 19

6” 

279 

241.0 

8 x 22

15 

1/2” 

95 

70 

4 x 15

20 

3/4” 

100 

75 

4 x 15

25 

1” 

125 

90 

4 x 19

40 

1 1/2” 

140 

105 

4 x 19

50 

2” 

155 

120 

4 x 19

65 

2 1/2” 

175 

140 

4 x 19

80 

3” 

185 

150 

8 x 19

100 

4” 

210 

175 

8 x 19

6” 

279 

241 

8 x 22

SNB-SNC ball valves

Installation and Maintenance Instructions

Emerson reserves the right to change the contents without notice 

page 4

6.5. Installation options

Ball valves can be equipped with various means of operation e.g. with hand lever, handwheel, 
electrical, pneumatic or hydraulic drive, or with a drive linked to a position controller for SNC 
control valves. The hand levers are supplied complete with a notched plate which allows the lever 
to be latched either in the end positions only (version ZE) or in the end positions and additionally 
in various intermediate positions (version Z). In addition, the hand lever can be provided with limit 
switches which indicate ‘open’ or ‘closed’.
For installation in exposed places, shaft extensions in various lengths are available for all sizes.

6.6. Bolted joints in the pipeline

All flange bolts must be used, even on low-pressure systems. The specified tightening toques for 
the bolts must always be adhered to.

6.7. Body variants

SNB and SNC ball valves have the same body dimensions. The face-to-face and mounting flange 
dimensions of the ball valve bodies vary according to the various standards. When used as an end 
of line valve, it must be secured in such a way that access to the isolating valve is restricted when 
in service.
It should also be noted that when a valve is used as the end valve of a pressurized system, the 
flange must be removed from the valve.

Dimensions

 

DN 

 

Tk 

n x d

mm 

 

inches 

mm mm mm

6.2. Dimensions of the mounting flanges for SNB-SNC ball and C valves DIN-PN16

* DN 150 ball valve only as ANSI 6” version available

Dimensions

 

DN 

 

Tk 

n x d

mm 

 

inches 

mm mm mm

6.3. Dimensions of the mounting flanges for SNB-SNC valves ANSI B 16.10 class 150 (lbs)

Dimensions

 

DN 

 

Tk 

n x d

mm 

 

inches 

mm mm mm

6.4. Dimensions of the mounting flanges for SNB-SNC ball and C valves JIS-10K

* Ball valves DN 150 only as ANSI 6” version available

Содержание NEOTECHA SNB Series

Страница 1: ...tional regulations are complied with The manufacturer reserves all rights to make technical changes and improvements at any time The use of these installation and maintenance instructions assumes that the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 Safety Please also read through these notes caref...

Страница 2: ...emperature of the valve can be up to a maximum of 200 C Suitable precautions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 3 5 Usage Restrictions Before the valve is installed a check shou...

Страница 3: ... a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve body material is cast onto the valve 3 8 Handling prior to installation on versions with protective covers only remove these immediately prior to installation protect against the effects of weather e g dampness...

Страница 4: ... various intermediate positions version Z In addition the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6...

Страница 5: ...ening torques for SNB SNC ball valves DIN PN16 and JIS 10K Recommended torques DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for SNB SNC ball valves ANSI B 16 10 class 150 lbs 6 8 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the valve spread the mounting flanges apart sufficiently using a suitable...

Страница 6: ...lves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an SNC series C valve should be used This type can also be fitted with various control orifice plates Refer to the flow characteristic d...

Страница 7: ...so that the possible cause of damage can be determined after removal Attention Check that the pipe is depressurized and drained With corrosive inflammable aggressive or toxic media ventilate the pipeline system Only allow assembly work to be carried out by qualified personnel see Section 2 3 Almost fully close the valve note position of the flat sections of the control shaft Loosen all flange bolt...

Отзывы: