background image

SNB-SNC ball valves

Installation and Maintenance Instructions

Emerson reserves the right to change the contents without notice 

page 2

Angular position

2.3.4. Flow characteristic for SNC control valves (without control orifice plate)

3. Sources of Danger

3.1. External chemical effects

The valve body is either made of stainless steel or is coated with a 2-part polyester paint. 
The coating can be attacked externally by strong solvents, leading to corrosion of the body. 
If damage of this nature occurs, the effects on the environment should be investigated and 
the damage to the coating made good in accordance with the manufacturer’s data. Stainless 
steel valve bodies are not suitable for use with chlorine gas.

3.2. Mechanical

When using hand levers and handwheels, it should be ensured that there is sufficient 
clearance everywhere for the operator’s hands, so that there is no risk of trapping.

3.3. Electrical

If static charges can lead to explosions, the valve must be earthed by means of the 
appropriate earthing accessory. As an alternative, valves with electrically conductive linings 
are available. For more information, please contact the supplier or manufacturer.

3.4. Thermal

The operating temperature of the valve can be up to a maximum of 200°C. Suitable 
precautions should be taken to protect against burns due to high or freezing temperatures. 
In particular, insulated gloves should be worn when using the hand lever, for example. 
In case of fire, the mechanical strength of the PTFE seals is no longer guaranteed above 
200°C.

2.3.5. Usage Restrictions

Before the valve is installed, a check should be made on the extent to which the coating of 
the surfaces is resistant to the intended medium. The same applies to stainless steel valves 
with no additional coating. Refer to appropriate literature or consult the manufacturer or 
distributor for advice on this.

2.3.6. Modification Prohibition

Mechanical modifications to the valves or the use of other manufacturer’s parts for repair 
purposes are not permissible, as otherwise safety is no longer guaranteed. Repair work 
must only be carried out by the manufacturer’s trained personnel. The manufacturer and 
supplier will accept no liability in the event of misuse.

2.3.7. Warning about foreseeable misuse

Valves and their accessories (e.g. operating elements) must not be misused as climbing 
aids.

2.3.8. Duty to comply with the instructions for operation, maintenance and servicing

These instructions form part of the delivery package and must be easily accessible to the user. They 
should be protected from soiling and kept in a suitable place.

Содержание NEOTECHA SNB Series

Страница 1: ...tional regulations are complied with The manufacturer reserves all rights to make technical changes and improvements at any time The use of these installation and maintenance instructions assumes that the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 Safety Please also read through these notes caref...

Страница 2: ...emperature of the valve can be up to a maximum of 200 C Suitable precautions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 3 5 Usage Restrictions Before the valve is installed a check shou...

Страница 3: ... a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve body material is cast onto the valve 3 8 Handling prior to installation on versions with protective covers only remove these immediately prior to installation protect against the effects of weather e g dampness...

Страница 4: ... various intermediate positions version Z In addition the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6...

Страница 5: ...ening torques for SNB SNC ball valves DIN PN16 and JIS 10K Recommended torques DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for SNB SNC ball valves ANSI B 16 10 class 150 lbs 6 8 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the valve spread the mounting flanges apart sufficiently using a suitable...

Страница 6: ...lves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an SNC series C valve should be used This type can also be fitted with various control orifice plates Refer to the flow characteristic d...

Страница 7: ...so that the possible cause of damage can be determined after removal Attention Check that the pipe is depressurized and drained With corrosive inflammable aggressive or toxic media ventilate the pipeline system Only allow assembly work to be carried out by qualified personnel see Section 2 3 Almost fully close the valve note position of the flat sections of the control shaft Loosen all flange bolt...