background image

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling
fan against all defects in workmanship and materials. You must be the original purchaser or user of the product
to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime from the date you purchased your ceiling fan.
All other components and accessories are covered by this warranty for one year from the date you purchased
your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other
accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable
time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan.
We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or
removal, reinstallation and shipping of the product to Emerson Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY
SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory
or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to

Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136.
Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest

authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized
service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit
since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does
not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal

wear and tear.

• Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are

voided when:

• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other
written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any
warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS
WARRANTY AND EMERSON ELECTRIC CO. IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such
damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of
repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above
exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

19

BP7333 CF750 MAYA ZEN  12/22/06  7:59 AM  Page 19

Содержание MAYA ZEN CF750ORB00

Страница 1: ...No F40BP73330000 Form No BP7333 UL Model No CF750 READ AND SAVE THESE INSTRUCTIONS Net Weight 28 6 Lbs MAYA ZEN 54 Ceiling Fan Owner s Manual CF750ORB00 Model No BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 1 ...

Страница 2: ...of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod 8 furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The shorter downrod 4 5 must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent...

Страница 3: ...not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE If you are uncertain of...

Страница 4: ...U L LIGHT A FAN MOTOR ASSEMBLY C CEILING COVER G LIGHT PLATE ASSEMBLY L FAN LIGHT WALL CONTROL N LOOSE PARTS BAG H LOWER GLASS B COUPLING COVER D UPPER DECORATIVE SCROLL K 4 5 DOWNROD M SW105 RECEIVER F FAN BLADES E BLADE FLANGE I HANGER BALL 8 DOWNROD ASSEMBLY NOTE Place the parts from the loose parts bags in a small container to keep them from being lost CARDBOARD SHIPPING RETAINER 2 PROTECTIVE ...

Страница 5: ...the ceiling cover This system allows you to regulate your ceiling fan speed airflow direction and light intensity An optional Emerson Electric SR110 Remote Control may also be used IMPORTANT Your ceiling fan will not function properly and may be damaged if used with any wall dimmer switch or control other than the Emerson controls listed above Electrical Requirements Preliminary Procedures How to ...

Страница 6: ...ure 3 4 Position the light kit plate assembly onto the fan motor assembly aligning one hole and the two keyholes 5 Attach the light kit plate assembly by inserting a M4 x 10mm serrated head screw into the hole Rotate the light kit plate assembly to align the key hole slots Attach the two remaining M4 x 10mm serrated head screws into the key hole slots Tighten the three screws securely Figure 4 6 T...

Страница 7: ...til the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 9 While pulling up on the downrod securely tighten the two setscrews in the motor coupling Figure 8 NOTE The two setscrews must be properly installed as described above o...

Страница 8: ...k and white leads that are 80 long Before installing fan measure up approx imately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 13 Slide the coupler cover on the downrod until it rests on the fan motor assembly Figure 11 14 For Use With The 8 Downrod Only Position the decorative upper scroll over the downrod Slide...

Страница 9: ... LEAST 7 Figure 15 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 17 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 16 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet bo...

Страница 10: ... box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician CAUTION To reduce the risk of electrical shock disconnect the electrical supply ci...

Страница 11: ...YELLOW FAN WIRE BLACK WHITE RECEIVER WIRE BLACK SUPPLY WIRE WHITE SUPPLY WIRE 4 After connections have been made separate the white and green wires from the black blue and yellow wires 5 Carefully turn the wires upward and insert them up through the open side of the hanger bracket and into the outlet box Push the green and white wires into one side of the outlet box push the black blue and yellow ...

Страница 12: ... pinched between the ceiling cover and the ceiling WARNING 8 EXTERNAL TOOTH LOCKWASHER 2 CEILING COVER 1 1 4 THREADED STUD 2 8 32 KNURLED KNOB 2 Figure 21 60 WATT max CANDELABRA BASE BULB 3 LIGHT KIT ASSEMBLY SOCKET 3 THREADED NIPPLE RUBBER WASHER FINIAL NUT HEX JAMNUT Figure 22 FINIAL NUT GLASS SHADE LIGHT KIT PLATE ASSEMBLY Figure 23 Final Assembly 1 Screw the two 1 1 4 threaded studs supplied i...

Страница 13: ...mall screwdriver and slide the levers firmly up or down 2 In the receiver slide the four switch levers to the same positions as set in the wall control Make sure the levers on both switches are in the same positions otherwise the fan will not operate The wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover The SW105 receiver is...

Страница 14: ...an installation is completed Figure 26 DECORATIVE FACEPLATE OUTLET BOX WALL CONTROL WALL CONTROL SCREW 2 FACEPLATE SCREW 2 HI MED LOW FAN OFF EMERSON LIGHT U L D L Figure 26 IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your Fan Light Wall Control Figure 27 has full control of your fan lights and airflow direction 1 T...

Страница 15: ...t harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tel...

Страница 16: ...16 Repair Parts 4 24 HI MED LOW FAN OFF EMERSON D L U L LIGHT 29 1 7 8 9 6 3 2 15 16 17 28 5 21 22 25 13 14 23 18 30 10 27 26 11 12 20 19 BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 16 ...

Страница 17: ...r External Tooth 8 32 2 9 Knob Knurled 8 32 2 10 Screw Washer Head M5 x 6mm 16 11 Screw Pan Head M5 x 12mm 11 12 Lockwasher M5 11 13 Screw Serrated Head M4 x 10mm 4 14 Kit Balancing 1 15 Cover Ceiling 1 763286 ORB 16 Scroll Decorative Upper 1 763303 ORB 17 Cover Coupling 1 763287 ORB 18 Housing Assembly Upper 1 763288 ORB 19 Glass Housing Center 1 763290 20 Harness Wiring 1 763302 21 Light Kit Pla...

Страница 18: ... sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling are 1 Raise coupling cover and tighten excessively not tightened securely setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blades 3 Check to be sure screws which to motor are loose attach the...

Страница 19: ...er You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also doe...

Страница 20: ...Part No F40BP73330000 Printed in China 12 06 Form No BP7333 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 20 ...

Отзывы: