1. Securely attach the hanger bracket to

the outlet box using the two screws
supplied with the outlet box (Figure 16).

How to Hang

Your Ceiling Fan

The fan must be hung with at least 7' of
clearance from floor to blades (Figure 15).

!

WARNING

The outlet box and joist must be securely
mounted and capable of supporting at
least 50 lbs. Use only a U.L. outlet box
listed as “Acceptable for Fan Support”.

!

WARNING

To reduce the risk of fire, electric shock,
or personal injury, mount fan to outlet box
marked “Acceptable for Fan Support”,
and use screws supplied with outlet box.
Most outlet boxes commonly used for
support of light fixtures are not
acceptable for fan support and may need
to be replaced. Consult a qualified
electrician if in doubt.

!

WARNING

CEILING

FLOOR

AT 

LEAST

7'

Figure 15

2. Carefully lift the fan and seat the

hanger ball/downrod assembly on the
hanger bracket that was just attached
to the outlet box (Figure 17). Be sure
the groove in the ball is lined up with
the tab on the hanger bracket
(Figure 16).

Hanger bracket must seat firmly against
outlet box. If the outlet box is recessed,
remove wall board until bracket contacts
box. If bracket and/or outlet box are not
securely attached, the fan could wobble
or fall.

!

WARNING

Failure to seat tab in groove could cause
damage to electrical wires and possible
shock or fire hazard.

!

WARNING

To avoid possible fire or shock, do not
pinch wires between the hanger
ball/downrod assembly and hanger
bracket.

!

WARNING

TWO SCREWS
SUPPLIED 
WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

NOTE: CEILING COVER, SUPPLY WIRES AND FAN 
WIRES OMITTED FOR CLARITY.

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD 
ASSEMBLY

Figure 16

Figure 17

9

BP7333 CF750 MAYA ZEN  12/22/06  7:59 AM  Page 9

Содержание MAYA ZEN CF750ORB00

Страница 1: ...No F40BP73330000 Form No BP7333 UL Model No CF750 READ AND SAVE THESE INSTRUCTIONS Net Weight 28 6 Lbs MAYA ZEN 54 Ceiling Fan Owner s Manual CF750ORB00 Model No BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 1 ...

Страница 2: ...of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod 8 furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The shorter downrod 4 5 must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent...

Страница 3: ...not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE If you are uncertain of...

Страница 4: ...U L LIGHT A FAN MOTOR ASSEMBLY C CEILING COVER G LIGHT PLATE ASSEMBLY L FAN LIGHT WALL CONTROL N LOOSE PARTS BAG H LOWER GLASS B COUPLING COVER D UPPER DECORATIVE SCROLL K 4 5 DOWNROD M SW105 RECEIVER F FAN BLADES E BLADE FLANGE I HANGER BALL 8 DOWNROD ASSEMBLY NOTE Place the parts from the loose parts bags in a small container to keep them from being lost CARDBOARD SHIPPING RETAINER 2 PROTECTIVE ...

Страница 5: ...the ceiling cover This system allows you to regulate your ceiling fan speed airflow direction and light intensity An optional Emerson Electric SR110 Remote Control may also be used IMPORTANT Your ceiling fan will not function properly and may be damaged if used with any wall dimmer switch or control other than the Emerson controls listed above Electrical Requirements Preliminary Procedures How to ...

Страница 6: ...ure 3 4 Position the light kit plate assembly onto the fan motor assembly aligning one hole and the two keyholes 5 Attach the light kit plate assembly by inserting a M4 x 10mm serrated head screw into the hole Rotate the light kit plate assembly to align the key hole slots Attach the two remaining M4 x 10mm serrated head screws into the key hole slots Tighten the three screws securely Figure 4 6 T...

Страница 7: ...til the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 9 While pulling up on the downrod securely tighten the two setscrews in the motor coupling Figure 8 NOTE The two setscrews must be properly installed as described above o...

Страница 8: ...k and white leads that are 80 long Before installing fan measure up approx imately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 13 Slide the coupler cover on the downrod until it rests on the fan motor assembly Figure 11 14 For Use With The 8 Downrod Only Position the decorative upper scroll over the downrod Slide...

Страница 9: ... LEAST 7 Figure 15 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 17 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 16 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet bo...

Страница 10: ... box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician CAUTION To reduce the risk of electrical shock disconnect the electrical supply ci...

Страница 11: ...YELLOW FAN WIRE BLACK WHITE RECEIVER WIRE BLACK SUPPLY WIRE WHITE SUPPLY WIRE 4 After connections have been made separate the white and green wires from the black blue and yellow wires 5 Carefully turn the wires upward and insert them up through the open side of the hanger bracket and into the outlet box Push the green and white wires into one side of the outlet box push the black blue and yellow ...

Страница 12: ... pinched between the ceiling cover and the ceiling WARNING 8 EXTERNAL TOOTH LOCKWASHER 2 CEILING COVER 1 1 4 THREADED STUD 2 8 32 KNURLED KNOB 2 Figure 21 60 WATT max CANDELABRA BASE BULB 3 LIGHT KIT ASSEMBLY SOCKET 3 THREADED NIPPLE RUBBER WASHER FINIAL NUT HEX JAMNUT Figure 22 FINIAL NUT GLASS SHADE LIGHT KIT PLATE ASSEMBLY Figure 23 Final Assembly 1 Screw the two 1 1 4 threaded studs supplied i...

Страница 13: ...mall screwdriver and slide the levers firmly up or down 2 In the receiver slide the four switch levers to the same positions as set in the wall control Make sure the levers on both switches are in the same positions otherwise the fan will not operate The wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover The SW105 receiver is...

Страница 14: ...an installation is completed Figure 26 DECORATIVE FACEPLATE OUTLET BOX WALL CONTROL WALL CONTROL SCREW 2 FACEPLATE SCREW 2 HI MED LOW FAN OFF EMERSON LIGHT U L D L Figure 26 IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your Fan Light Wall Control Figure 27 has full control of your fan lights and airflow direction 1 T...

Страница 15: ...t harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or tel...

Страница 16: ...16 Repair Parts 4 24 HI MED LOW FAN OFF EMERSON D L U L LIGHT 29 1 7 8 9 6 3 2 15 16 17 28 5 21 22 25 13 14 23 18 30 10 27 26 11 12 20 19 BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 16 ...

Страница 17: ...r External Tooth 8 32 2 9 Knob Knurled 8 32 2 10 Screw Washer Head M5 x 6mm 16 11 Screw Pan Head M5 x 12mm 11 12 Lockwasher M5 11 13 Screw Serrated Head M4 x 10mm 4 14 Kit Balancing 1 15 Cover Ceiling 1 763286 ORB 16 Scroll Decorative Upper 1 763303 ORB 17 Cover Coupling 1 763287 ORB 18 Housing Assembly Upper 1 763288 ORB 19 Glass Housing Center 1 763290 20 Harness Wiring 1 763302 21 Light Kit Pla...

Страница 18: ... sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling are 1 Raise coupling cover and tighten excessively not tightened securely setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blades 3 Check to be sure screws which to motor are loose attach the...

Страница 19: ...er You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also doe...

Страница 20: ...Part No F40BP73330000 Printed in China 12 06 Form No BP7333 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 BP7333 CF750 MAYA ZEN 12 22 06 7 59 AM Page 20 ...

Отзывы: