manualshive.com logo in svg
background image

7

emersonfans.com

Please contact 1-800-654-3545 for further assistance

ETL Model No.: LK70LED/LK71LED/LK72LED/LK74LED/LK77LED/

LK80LED/LK81LED/LK83LED/LK90LED/LK91LED/LK140LED/LK141LED

FAN SPEED 
CONTROL CHAIN

GLASS 
BOWL

LED LIGHT FIXTURE 
ASSEMBLY CHAIN

Figure 9

3.10

Insert the LED light fixture assembly chain and the fan
speed control switch chain through the hole in the glass
bowl (Figure 9).

Gently place the glass bowl onto the LED light fixture
assembly (Figure 9). 

NOTE: It is critical that the fan chain(s) are aligned with
hole(s) in the glass bowl for smooth operation of the fan
switch(es).

3.11

Route the fan speed control chain through the offset
hole of the bowl cap (Figure 10).

Route the LED light fixture assembly chain through the
center hole of the bowl cap (Figure 10).

Place the bowl cap onto the threaded stud and against
the glass bowl.

NOTE: The bowl cap comes with three options: no holes,
one hole and two holes for pull chain options.

Install and tighten the threaded finial nut onto the
threaded stud of the LED light fixture assembly
(Figure 10).

NOTE: The finial nut comes with two options: no holes
and one hole for pull chain options.

NOTE: It is advisable to periodically check the tightness
of the finial nut.

FAN SPEED 
CONTROL CHAIN

LED LIGHT FIXTURE 
ASSEMBLY CHAIN

BOWL CAP

FINIAL NUT

THREADED STUD

GLASS
BOWL

Figure 10

COUPLING

WOOD PENDANT

FAN SPEED 
CONTROL CHAIN

GLASS 
BOWL

WOOD PENDANT

COUPLING

LED LIGHT FIXTURE 
ASSEMBLY CHAIN

Figure 11

3. Installation on Emerson Fans Having a

Modular Switch Cup with Center Screw

(Continued)

3.12

Connect the wood pendant (supplied) to the switch pull
chain by sliding the wood pendant (small hole first) onto
the pull chain (Figure 11).

Attach the chain coupling to the end of the chain and
allow the wood pendant to fall down over the
coupling (Figure 11).

BP7502 LK70, 80, 90, 140 LED  10/13/15  3:02 AM  Page 7

Содержание LK140LED

Страница 1: ...D LK72LED LK74LED LK77LED Revision 151015 LK80LED LK81LED LK83LED LK90LED LK91LED LK140LED LK141LED www emersonfans com LK70LED LK71LED LK72LED LK74LED LK77LED Net Weight 2 6 Lbs Net Weight 2 9 Lbs LK90LED LK91LED Net Weight 2 6 Lbs LK140LED LK141LED Net Weight 3 5 Lbs READ AND SAVE THESE INSTRUCTIONS 1 800 654 3545 Ceiling Fan LED Light Fixture Owner s Manual Model Numbers BP7502 LK70 80 90 140 L...

Страница 2: ... electrician WARNING To reduce the risk of possible fire and electrical shock install only on Emerson Ceiling Fan models CF552 CF542 CF621 CF670 CF652 CF654 and CF742 in damp locations with the WLP100 wet location plate Permissible to use this light kit on all Emerson CF model ceiling fans installed in indoor locations 1 Read your Owner s Manual carefully before installing the light fixture Retain...

Страница 3: ... WARNING 1 1 Open carton containing light fixture Remove top half of styrofoam unit Remove parts and check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration A B C D E F H G PACKAGE CONTENTS Part Description Quantity A Hex Nut 1 B Lockwasher 1 C LED Light Fixture Assembly 1 D Glass Shade 1 E Bowl Caps 3 F Finial Nuts ...

Страница 4: ...sed electrician WARNING Please call Emerson technical support at 1 800 654 3545 if you have any questions about installation and operation of this light fixture Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be pr...

Страница 5: ...ht fixture assembly through the center hole in the switch cup Figure 3 and thread the switch cup onto the LED light fixture assembly To prevent the wires from twisting hold wires taut while installing LED light fixture assembly onto the switch cup Tighten the LED light fixture assembly until the fan switch chain aligns and is routed through one of the holes in the fixture flange Figure 3 Insert th...

Страница 6: ...ED light fixture assembly onto the cover plate Figure 8 Reinstall and tighten securely the three screws that were previously removed in Step 3 2 into the switch cup Figure 8 WARNING To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors To avoid possible fire or electric shock be careful not to pinch wires between switch cup and the cover p...

Страница 7: ...ainst the glass bowl NOTE The bowl cap comes with three options no holes one hole and two holes for pull chain options Install and tighten the threaded finial nut onto the threaded stud of the LED light fixture assembly Figure 10 NOTE The finial nut comes with two options no holes and one hole for pull chain options NOTE It is advisable to periodically check the tightness of the finial nut FAN SPE...

Страница 8: ...h Housing 4 2 Remove the switch housing cover from switch housing below ceiling fan by unscrewing the two switch housing cover screws retain the screws for future use Figure 12 REMOVE WIRE CONNECTOR WHITE WIRE BLUE WIRE SWITCH HOUSING REMOVE WIRE CONNECTOR 4 3 Carefully pull down white and blue wires from the switch housing and remove wire connectors Figure 13 Retain wire connectors for future ins...

Страница 9: ...ed in Step 4 3 to make connections Figures 15 and 16 Figure 16 SWITCH HOUSING 14MM THREADED STUDS 2 Figure 17 4 7 Install the two 14mm threaded studs into the switch housing Figure 17 WARNING To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors DOUBLE KNURLED KNOBS 2 LIGHT FIXTURE CONTROL CHAIN SWITCH COVER LED LIGHT FIXTURE ASSEMBLY SWIT...

Страница 10: ...the finial nut FAN SPEED CONTROL CHAIN LED LIGHT FIXTURE ASSEMBLY CHAIN BOWL CAP FINIAL NUT THREADED STUD GLASS BOWL Figure 20 COUPLING WOOD PENDANT FAN SPEED CONTROL CHAIN GLASS BOWL WOOD PENDANT COUPLING LED LIGHT FIXTURE ASSEMBLY CHAIN Figure 21 4 Installation on Emerson Fans Having a Two Piece Die Cast Switch Housing Continued 4 11 Connect the wood pendant supplied to the switch pull chain by ...

Страница 11: ...or authorized service center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling im...

Страница 12: ...s com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Form No BP7502 Part No F40BP75020000 ETL Model No LK70LED LK71LED LK72LED LK74LED LK77LED Revision 151015 LK80LED LK81LED LK83LED LK90LED LK91LED LK140LED LK141LED Printed in China 10 15 BP7502 LK70 80 90 140 LED 10 13 15 3 02 AM Page 12 ...