background image

17.

Loosen the two setscrews in motor coupling if
necessary. Separate, untwist and unkink the
three 80” motor leads. Route the motor lead
wires through the desired downrod. Align the
clevis pin holes in the downrod with the holes in
the motor coupling. Install the clevis pin and
secure with the hairpin clip (Figure 7). The clevis
pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through
the hole near the end of the clevis pin until the
curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the
clevis pin is properly installed.

18.

While pulling up on the downrod, securely tighten
the two setscrews in the motor coupling
(Figure 8).

NOTE: The two setscrews must be properly
installed as described above, or fan wobble could
result.

20.

12” Or Optional Longer Downrod Installation
ONLY: 

Slide the decorative lower scroll over the

12” downrod to rest upon the fan motor housing
(Figure 9).

DECORATIVE 
LOWER SCROLL

UPPER GLASS 
SHADE

9" DOWNROD 
(or longer)

MOTOR 
HOUSING

Figure 9

6

COUPLING COVER

DOWNROD

MOTOR HOUSING

UPPER GLASS 
SHADE

Figure 8

21.

Position the decorative scroll end over the edge
of the uplight glass shade and slide into one of
the legs of the decorative lower scroll.

22.

Assemble the scroll end and lower scroll using the
two screws (supplied). Assemble the remaining
two legs and ends as described (Figure 10).

23.

Slide the decorative upper scroll over the
downrod engaging the pin of the decorative lower
scroll into one hole of the decorative upper scroll
and secure screw in collar of the decorative
upper scroll (Figure 11).

24.

Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large
opening at the top (Figure 11).

U.L. Model No.: CF820

U.L. Model No.: CF820

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.

WARNING

!

IMPORTANT

A.

If you have installed the 12” or optional longer
downrod and are planning to install the
decorative scrolls, proceed with Step 20.

B.

If you have installed the 6” downrod, skip
Step 20 and continue with Step 24.

DOWNROD

CLEVIS 
PIN

UPPER GLASS 
SHADE

FAN MOTOR 
HOUSING

HAIRPIN
CLIP

SETSCREWS

CLEVIS PIN

MOTOR
COUPLING

DOWNROD

HAIRPIN
CLIP

Figure 7

UPPER GLASS 
SHADE

DECORATIVE 
SCROLL END 
SCREW (2 per 
assembly)

DECORATIVE 
LOWER SCROLL

DECORATIVE 
SCROLL END

EDGE OF 
GLASS

Figure 10

19.

Be sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on
the downrod until it rests on the motor housing.
Be sure that the coupling cover is oriented
correctly (Figure 8).

Содержание LA FAYETTE CF820ORB00

Страница 1: ...AD AND SAVE THESE INSTRUCTIONS Part No F40BP73510000 Form No BP7351 U L Model No CF820 Net Weight 37 0 Lbs Model Numbers LA FAYETTE Ceiling Fan Owner s Manual CF820ORB00 Oil Rubbed Bronze CF820PW00 Pewter ...

Страница 2: ...The longer downrod 12 furnished with the ceiling fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 6 downrod supplied is to be used for shorter ceilings 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades 6 Follow the recommended instructions for the proper method of wiring your ceili...

Страница 3: ... injury or property damage WARNING WARNING 1 Open styrofoam unit containing fan Remove upper and center sections of styrofoam unit Remove parts and check to see that you have received the following a One Fan Motor and Housing Assembly b One Ceiling Cover c Five Fan Blades d Five Flange Assemblies e One Coupling Cover f One Hanger Bracket g One 12 Downrod Hanger Ball Assembly h One 6 Downrod i One ...

Страница 4: ... 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 lbs or Less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and ma...

Страница 5: ...pin connector from the uplight kit assembly connect the fan motor housing white wire single pin connector to the white wire single pin connector from the uplight kit assembly Figure 4 Be sure all wire connectors are fully engaged To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign object...

Страница 6: ...s shade and slide into one of the legs of the decorative lower scroll 22 Assemble the scroll end and lower scroll using the two screws supplied Assemble the remaining two legs and ends as described Figure 10 23 Slide the decorative upper scroll over the downrod engaging the pin of the decorative lower scroll into one hole of the decorative upper scroll and secure screw in collar of the decorative ...

Страница 7: ...ed electrician if in doubt WARNING 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 14 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 13 OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 14 To avoid possible fire or shock do not pinch wires between the hanger ball d...

Страница 8: ...t before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 15 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 15 3 Using wire connectors supplied...

Страница 9: ...until studs protrude through the holes in the ceiling cover Figure 18 8 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 18 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 9 Your ceiling fan in now installed and wired Proceed to Switch Housing Do...

Страница 10: ...ousing Downlight Installation SWITCH HOUSING SWITCH HOUSING PLATE SWITCH HOUSING 9 PIN CONNECTOR FAN ASSEMBLY 9 PIN CONNECTOR Figure 21 6 Position the switch housing assembly onto the switch housing plate and secure using the three switch housing screws supplied Figure 22 7 Install three 40 watt max candelabra light bulbs not supplied into the downlight sockets Figure 22 8 Remove the rubber washer...

Страница 11: ...Wall Control and Receiver Figure 24 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scre...

Страница 12: ...en tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to ra...

Страница 13: ... smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories ...

Страница 14: ...14 Repair Parts U L Model No CF820 U L Model No CF820 28 29 13 30 15 16 1 7 9 3 2 18 6 35 17 24 23 22 19 20 21 33 34 27 31 29 32 5 8 4 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 10 11 26 14 25 12 ...

Страница 15: ...ssembly 1 763536 ORB 763536 PW 24 Glass Assembly Upper 1 763534 763535 25 Flange Assembly 5 per set 763480 ORB 763480 PW 26 Blade Assembly 5 per set 763486 ORB 763486 PW 27 Harness Wiring Reverse Modular Aux Capacitor 1 763528 763528 28 Housing Switch Cup 1 763484 ORB 763484 PW 29 Lower Light Fitter Assembly 1 763531 763531 Washer Rubber 1 Washer Flat 1 Jamnut Hex 1 8 27 NPS 1 30 Glass Lower Shade...

Страница 16: ...an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The g...

Отзывы: