The outlet box and joist must be securely mounted
and capable of supporting at least 50 lbs. Use only a
U.L. outlet box listed as “Acceptable for Fan Support
of 50 lbs. or Less”.

WARNING

!

How to Hang

Your Ceiling Fan 

AT LEAST

7'

FLOOR

CEILING

Figure 12

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 12). Do NOT hang this
fan on an 8’ ceiling when using the 12” downrod.

WARNING

!

1.

Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box
(Figure 13).

U.L. Model No.: CF820

DECORATIVE 
UPPER SCROLL

DOWNROD

CEILING
COVER

SCREW

PIN

HANGER
BALL

SETSCREW

DOWNROD

Figure 11

27.

You have now completed the initial assembly of
your new ceiling fan. You can now proceed with
hanging and wiring your fan.

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET 
BOX

Figure 13

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support of 50 lbs. or Less”, and use screws
supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.

WARNING

!

2.

Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 14). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 13).

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

Figure 14

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and the
hanger bracket.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

25.

Reinstall the hanger ball on the downrod
as follows. Route the motor leads through the
hanger ball and slide the hanger ball over the
downrod (Figure 11). Install the pin through the
holes at the top of the downrod and slide the
hanger ball up the downrod, aligning the ball so
the pin is captured in the groove in the top of the
hanger ball. Pull the hanger ball up tight against
the pin and securely tighten the setscrew in the
hanger ball. A loose setscrew could create fan
wobble.

26.

The blue, black, white, and yellow leads exiting
the downrod are 80-inches long. Before installing
the fan, measure up approximately 6 to 9-inches
above the ball/downrod assembly. Cut off excess
leads and strip back insulation 1/2-inch from end
of leads.

NOTE: CEILING COVER, SUPPLY WIRES
AND FAN WIRES OMITTED FOR CLARITY.

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

Содержание LA FAYETTE CF820ORB00

Страница 1: ...AD AND SAVE THESE INSTRUCTIONS Part No F40BP73510000 Form No BP7351 U L Model No CF820 Net Weight 37 0 Lbs Model Numbers LA FAYETTE Ceiling Fan Owner s Manual CF820ORB00 Oil Rubbed Bronze CF820PW00 Pewter ...

Страница 2: ...The longer downrod 12 furnished with the ceiling fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 6 downrod supplied is to be used for shorter ceilings 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades 6 Follow the recommended instructions for the proper method of wiring your ceili...

Страница 3: ... injury or property damage WARNING WARNING 1 Open styrofoam unit containing fan Remove upper and center sections of styrofoam unit Remove parts and check to see that you have received the following a One Fan Motor and Housing Assembly b One Ceiling Cover c Five Fan Blades d Five Flange Assemblies e One Coupling Cover f One Hanger Bracket g One 12 Downrod Hanger Ball Assembly h One 6 Downrod i One ...

Страница 4: ... 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 lbs or Less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and ma...

Страница 5: ...pin connector from the uplight kit assembly connect the fan motor housing white wire single pin connector to the white wire single pin connector from the uplight kit assembly Figure 4 Be sure all wire connectors are fully engaged To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign object...

Страница 6: ...s shade and slide into one of the legs of the decorative lower scroll 22 Assemble the scroll end and lower scroll using the two screws supplied Assemble the remaining two legs and ends as described Figure 10 23 Slide the decorative upper scroll over the downrod engaging the pin of the decorative lower scroll into one hole of the decorative upper scroll and secure screw in collar of the decorative ...

Страница 7: ...ed electrician if in doubt WARNING 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 14 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 13 OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 14 To avoid possible fire or shock do not pinch wires between the hanger ball d...

Страница 8: ...t before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 15 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 15 3 Using wire connectors supplied...

Страница 9: ...until studs protrude through the holes in the ceiling cover Figure 18 8 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 18 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 9 Your ceiling fan in now installed and wired Proceed to Switch Housing Do...

Страница 10: ...ousing Downlight Installation SWITCH HOUSING SWITCH HOUSING PLATE SWITCH HOUSING 9 PIN CONNECTOR FAN ASSEMBLY 9 PIN CONNECTOR Figure 21 6 Position the switch housing assembly onto the switch housing plate and secure using the three switch housing screws supplied Figure 22 7 Install three 40 watt max candelabra light bulbs not supplied into the downlight sockets Figure 22 8 Remove the rubber washer...

Страница 11: ...Wall Control and Receiver Figure 24 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scre...

Страница 12: ...en tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to ra...

Страница 13: ... smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories ...

Страница 14: ...14 Repair Parts U L Model No CF820 U L Model No CF820 28 29 13 30 15 16 1 7 9 3 2 18 6 35 17 24 23 22 19 20 21 33 34 27 31 29 32 5 8 4 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 10 11 26 14 25 12 ...

Страница 15: ...ssembly 1 763536 ORB 763536 PW 24 Glass Assembly Upper 1 763534 763535 25 Flange Assembly 5 per set 763480 ORB 763480 PW 26 Blade Assembly 5 per set 763486 ORB 763486 PW 27 Harness Wiring Reverse Modular Aux Capacitor 1 763528 763528 28 Housing Switch Cup 1 763484 ORB 763484 PW 29 Lower Light Fitter Assembly 1 763531 763531 Washer Rubber 1 Washer Flat 1 Jamnut Hex 1 8 27 NPS 1 30 Glass Lower Shade...

Страница 16: ...an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The g...

Отзывы: