be mated correctly (color-to-color)
before they can be engaged. Make
sure the connectors close properly.

7. Connect the white wires from the light

fitter to the white wire in the switch
housing (Figure 5). Connect the black
wire from the light fitter to the blue wire
in the switch housing.

8. Position the light fitter into the switch

housing assembly (Figure 6) so that the
three mounting holes in the light fitter
align with the three threaded holes in
the switch housing. Install three 10-24 x
22mm pan head screws and tighten
securely.

CAUTION: Before installing and tight-
ening the screws, be sure there are no
wires pinched between the light fitter
and the switch housing.

4. Position the blade flange on the motor

hub so that the screws in the blade
flange align with the two threaded
holes in the motor hub. Tighten the
two screws securely. Repeat this
procedure for the remaining two blade
assemblies.

5. Insert the motor connector through the

center hole in the switch housing
assembly (Figure 4). Position the
switch housing so that the slotted holes
align with the smaller threaded holes in
the coupling. Then install three
8-32 x 12mm pan head screws with
lockwashers (supplied). Install three
1/4-20 x 11mm pan head screws with
lockwashers (supplied) in the larger
threaded holes. Tighten the screws.

6. Engage the connector of the switch

housing assembly with the motor con-
nector (Figure 4). The two connectors
are keyed and color-coded and must

BLADE 
FLANGE

1/4-20 x 11mm PAN 
HEAD SCREW WITH 
LOCKWASHER (2)

MOTOR HUB

Figure 3

6

SWITCH HOUSING 
ASSEMBLY

MOTOR 
CONNECTOR

SWITCH HOUSING 
CONNECTOR

COUPLING

1/4-20 x 11mm PAN HEAD 
SCREW WITH LOCKWASHER

8-32 x 12mm PAN HEAD 
SCREW WITH LOCKWASHER

LIGHT FITTER

SWITCH HOUSING 
ASSEMBLY

WHITE WIRES

BLACK WIRE

BLUE
WIRE

LIGHT FITTER

10-24 x 22mm PAN 
HEAD SCREW (3)

SWITCH HOUSING 
ASSEMBLY

Figure 4

Figure 5

Figure 6

Emerson Structures  1/24/05  8:22 AM  Page 6

Содержание KF200NI00

Страница 1: ...5 READ AND SAVE THESE INSTRUCTIONS KF200NI00 Brushed Nickel with Black Brushed Nickel Blades KF200OZ00 Olde Bronze with Black Teak Blades STRUCTURES Ceiling Fan Owner s Manual Emerson Fans Designed by Model Numbers Emerson Structures 1 24 05 8 22 AM Page 1 ...

Страница 2: ...de clearance for a 9 foot ceiling The 6 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to pre vent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed elect...

Страница 3: ...NING a Fan motor and housing assembly b One ceiling cover c One coupling cover d Three fan blades e Three blade flanges f One hanger bracket g One hanger ball downrod assembly h One switch housing assembly i One rod support assembly j Three decorative rod assemblies k Six decorative screws bagged l One light fitter m One lower glass n One 75 watt halogen bulb o One 6 downrod p One remote control t...

Страница 4: ...ded into two sections The first section REMOTE CONTROL PROCEDURES describes how to install the 9 volt alka line battery not supplied in the remote control transmitter and how to set the operating frequency of the transmitter and receiver These instructions must be performed prior to the installation of the ceiling fan as described in the second section CEILING FAN PROCE DURES REMOTE CONTROL PROCED...

Страница 5: ...ty is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceil ing fan must be properly grounded as a precaution against possible electri cal shock WARNING How to Assemble Your Ceiling Fan 1 Mount the fan blades to the blade flanges using three 10 24 x 9mm truss head screws and three fiber washers supplied Figure 2 2 Remove and disca...

Страница 6: ... this procedure for the remaining two blade assemblies 5 Insert the motor connector through the center hole in the switch housing assembly Figure 4 Position the switch housing so that the slotted holes align with the smaller threaded holes in the coupling Then install three 8 32 x 12mm pan head screws with lockwashers supplied Install three 1 4 20 x 11mm pan head screws with lockwashers supplied i...

Страница 7: ...step 18 NOTE If you have an eight foot ceiling you will have to use the 6 downrod supplied in order to maintain the nec essary blade to floor clearance of seven feet 11 Unscrew the two upper setscrews Figure 8 until they clear the inside of the motor coupling Then separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the d...

Страница 8: ...otor housing Figure 10 The decorative rods must be oriented so that they lean in towards the downrod Do not tighten the rod screws at this time 16 Slide the rod support assembly up the downrod until the threaded holes in the rod support align with the holes in the decorative rod assemblies Figure 11 Secure the decorative rods to the rod support using three decorative rod screws do not tighten the ...

Страница 9: ...et box using the two screws supplied with the outlet box Figure 14 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To a...

Страница 10: ...e wire connectors except for the ground wire 2 Refer to Figure 16 and 17 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiv...

Страница 11: ...BLACK WHITE RED BLACK WHITE HANGER BALL GREEN WIRE GROUND FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE WHITE BLUE Figure 17 3 Push the wires and connectors up into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs...

Страница 12: ...d release the button The light will turn on at the light level previously set see step 4 6 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the reversing switch Figure 21 and turn the fan on again The blades will turn in the opposite direction and reverse the airflow STORAGE BRACKET HI OFF LOW MED Figure 20 Figure 21 Installation o...

Страница 13: ...rference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recep...

Страница 14: ...er or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened securely setscrew se...

Страница 15: ...ng 762708 NI 762708 OZ 21 Blade Set full set for one fan 762635 10 762635 11 22 Flange Set full set for one fan 762725 NI 762725 OZ 23 Harness Assembly Wiring 762719 762719 24 Housing Switch 762715 NI 762715 OZ 25 Fitter Light 762716 762716 26 Glass Lower 762718 762718 1 27 Bulb Halogen 75 watt 762737 762737 28 Downrod 6 761631 43 761631 44 29 Transmitter Remote Control 761970 1 761970 1 30 Receiv...

Страница 16: ...esponsible for all insurance freight or other transportation charges to our fac tory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any...

Отзывы: