68 • iPro Case Controller I&O Manual FM V1.01
026-1738 Rev 1
MTSet
Medium/Dual Temperature setpoint
-40-90°
DB
Deadband
1-45°
CrE
Control Type
Standard, Suction, Superheat Only,
Superheat & Suction
DrE
Door Enable
Yes/No
Drd
Door - Refrigeration ON Delay
0:00-20:00 min:sec
DrA
Alarm Active Delay
0:00-20:00 min:sec
CSE
Clean Switch Active
Yes/No
CSd
Clean Switch - Refrigeration ON Delay
0:00-60:00 min:sec
TempMode
Controller is LT, MT or Dual Temp Capable
LT, MT or Dual Temp
CTM
Control Temperature Mode-Calculation method for locally connected
sensors
Average/Minimum/Maximum
DrMd
Door operation mode
Alarm/Shutdown
CSMd
Clean Switch operation mode
Normal/BackOn
SSCP
Superheat and suction control temperature calculation method
Average/Min/Max-Local or Average/Min/
Max-Lineup
SupHtSet
Superheat setpoint for EEV1-3
1-40°
Electronic Valve Parameters
EEV
EEV driver
Not Used/XEV20D
EEVCnt
EEV Count
0-3 Valves
XEV20D-1 V1
Valve assigned to XEV20_1 Valve 1 position
EEPR or EEV1-3
XEV20D-1 V2
Valve assigned to XEV20_1 Valve 2 position
XEV20D-2 V1
Valve assigned to XEV20_2 Valve 1 position
XEV20D-2 V2
Valve assigned to XEV20_2 Valve 1 position
XEV20 Parameters
AIC01_1
XEV20_1 - Configuration of Probe 1
Not Used/Discharge 1-6/
Defrost Term 1-6/Return 1-3/Coil Out 1-3
AIC02_1
XEV20_1 - Configuration of Probe 2
AIC03_1
XEV20_1 - Configuration of Probe 3
AIC04_1
XEV20_1 - Configuration of Probe 4
Ofs01_1
XEV20_1 - Probe 1 offset
-100-100
Ofs02_1
XEV20_1 - Probe 2 offset
Ofs03_1
XEV20_1 - Probe 3 offset
Ofs04_1
XEV20_1 - Probe 4 offset
AIT01_1
XEV20_1 - Sensor Type of Probe 1
CPC Thermistor/NTC/PTC/PT1000
AIT02_1
XEV20_1 - Sensor Type of Probe 2
CPC Thermistor/NTC/PTC/PT1000
AI0304_TYPE_1
XEV20_1 - Probe 3 and Probe 4 type
Resistive/Voltage/Current
AIT03_1
XEV20_1 - Sensor Type of Probe 3
CPC Thermistor/NTC/PTC/PT1000/
0-1VDC/0-5VDC/0-10VDC/0-20mA/
4-20mA
AIT04_1
XEV20_1 - Sensor Type of Probe 4
AI03_1_min
XEV20_1 - Probe 3 value at min
Selectable based on probe type
AI03_1_max
XEV20_1 - Probe 3 value at max
AI04_1_min
XEV20_1 - Probe 4 value at min
AI04_1_max
XEV20_1 - Probe 4 value at max
Table 16-1