Instruction Manual
D500242X012
A31A Cryogenic-Rotary Valve
February 2019
16
Figure 6. Anti‐Blowout Protection Detail
PACKING
FLANGE
ANTI‐BLOWOUT
FLANGE
SHAFT SHOULDER
SHAFT
HEX
NUT
STUD
PACKING
FOLLOWER
HEX
NUT
TYPICAL PTFE
V‐RING
PACKING
A7090 / IL
SHAFT
STUD
HEX NUT
PACKING
FOLLOWER
V‐RING PACKING
OUT'BD BEARING
PACKING
RING
ANTI‐BLOWOUT
SHAFT
SHOULDER
3‐ THROUGH 12‐INCH SIZES
14‐ THROUGH 24‐INCH SIZES
16B5082 / DOC
Disassembly
WARNING
The edges of a rotating valve disk (key 3) have a shearing effect that might result in personal injury. To avoid personal
injury, keep clear of the disk edges when rotating the disk.
CAUTION
When removing the actuator from the valve, do not use a hammer or similar tool to drive the lever off the valve shaft.
Driving the lever or actuator off the valve shaft could damage the valve internal parts.
If necessary, use a wheel puller to remove the lever or actuator from the valve shaft. It is okay to tap the wheel puller screw
lightly to loosen the lever or actuator, but hitting the screw with excessive force could also damage internal valve parts.
Never use a wrench or pliers on the drive shaft. A damaged shaft could cut the packing and allow leakage.
Unless otherwise indicated, key numbers and part names are listed in figures 7 and 8.
1. Remove the actuator and valve, as an assembly, from the pipeline, and then remove the actuator from the valve.
Note