dLE 

Energy saving cycle duration on working days 

00:00  00:00  Pr2 

hh:mm 

iSE 

Energy saving cycle starting time on weekends 

00:00  00:00  Pr2 

hh:mm 

dSE 

Energy saving cycle duration on weekends 

00:00  00:00  Pr2 

hh:mm 

dd1 

Sunday defrost 

no 

no 

Pr2 

 

dd2 

Monday defrost 

no 

no 

Pr2 

 

dd3 

Tuesday defrost 

no 

no 

Pr2 

 

dd4 

Wednesday defrost 

no 

no 

Pr2 

 

dd5 

Thursday defrost 

no 

no 

Pr2 

 

dd6 

Friday defrost 

no 

no 

Pr2 

 

dd7 

Saturday defrost 

no 

no 

Pr2 

 

Ld1 

1st defrost starting time 

nu 

00:00  Pr2 

hh:mm 

Ld2 

2nd defrost starting time 

nu 

00:00  Pr2 

hh:mm 

Ld3 

3rd defrost starting time 

nu 

00:00  Pr2 

hh:mm 

Ld4 

4th defrost starting time 

nu 

00:00  Pr2 

hh:mm 

Ld5 

5th defrost starting time 

nu 

00:00  Pr2 

hh:mm 

Ld6 

6th defrost starting time 

nu 

00:10  Pr2 

hh:mm 

Adr 

Serial address 

Pr2 

 

bAU 

Baudrate 

9.6 

9.6 

Pr2 

 

onC 

ONOFF button configuration (left upper side) 

nU 

nU 

Pr2 

 

on2 

ONOFF button timed (3sec) configuration (left upper 

side) 

oFF 

oFF 

Pr2 

 

LGC 

Light button configuration (left upper side) 

LiG 

LiG 

Pr2 

 

LG2 

Light button timed (3sec) configuration (left upper 

side) 

nU 

nU 

Pr2 

 

dFC 

DEF button configuration (left upper side) 

Pb2 

Pb2 

Pr2 

 

dF2 

DEF button timed (3sec) configuration (left upper side) 

dEF 

dEF 

Pr2 

 

dnC 

Down button configuration 

Std 

Std 

Pr2 

 

dn2 

Down button timed (3sec) configuration 

Lnt 

Lnt 

Pr2 

 

dP1 

Probe P1 value visualization 

 

 

Pr1 

°C 

dP2 

Probe P2 value visualization 

 

 

Pr1 

°C 

dP3 

Probe P3 value visualization 

 

 

Pr1 

°C 

dP4 

Probe P4 value visualization 

 

 

Pr1 

°C 

SPd 

Instantaneous compressor speed (RPM * 10) 

 

 

Pr1 

Hz 

rSE 

Real regulation Set Point (SET + HES + SETd) 

 

 

Pr1 

°C 

FdY 

Firmware release date: day 

 

 

Pr1 

 

FMn 

Firmware release date: month 

 

 

Pr1 

 

FYr 

Firmware release date: year 

 

 

Pr1 

 

rEL 

Firmware release 

 

 

Pr1 

 

Ptb 

Parameter map version 

Pr1 

 

Содержание Dixell XRi60CH

Страница 1: ...porator s probe P2P At the end of defrost dripping time is started its length is set in the Fdt parameter With Fdt 0 the dripping time is disabled 3 2 1 PRE DEFROST The par dAF enable a pre defrost phase During this interval the regulation setpoint will be moved to the value SET 1 C or SET 1 F The defrost phase starts as soon as the regulation temperature reach the pre defrost setpoint or when the...

Страница 2: ...the maximum compressor speed FMA until reaching the CCS setpoint The maximum interval of time for any PULL DOWN is defined from par CCt 8 2 OIL MIGRATION CONTROL VALID ONLY FOR VSC To avoid oil migration during variable speed compressor operation a lubrication control is implemented If the compressor works with a speed lower than the MnP threshold for tMi time then the compressor speed will be inc...

Страница 3: ...T HY1 Variable Speed Compressor Differential in normal mode 0 1 to 25 5 C 1 to 45 F odS Output activation delay at start up 0 to 255 min this function is enabled after the instrument power on and delays the output activations AC Anti short cycle delay 0 to 999 sec minimum interval between a compressor stop and the following restart AC1 Anti short cycle delay 2nd compressor 0 to 999 sec delay befor...

Страница 4: ...ating CL cooling SAA Set Point for auxiliary regulator 100 0 to 150 0 C 148 to 302 F it defines the room temperature set point to switch auxiliary relay SHY Auxiliary regulator differential 0 1 to 25 5 C 1 to 45 F differential for auxiliary output set point ACH CL AUX Cut in is SAA SHY AUX Cut out is SAA ACH Ht AUX Cut in is SAA SHY AUX Cut out is SAA ArP Probe selection for auxiliary regulator nP...

Страница 5: ...lease for internal use Ptb Parameter table code readable only 13 DIGITAL INPUTS The first digital input terminals 18 20 is enabled with P3P n The free voltage digital inputs are programmable by the i1F parameter 13 1 GENERIC ALARM i1F EAL As soon as the digital input is activated the unit will wait for did time delay before signalling the EAL alarm message The outputs status doesn t change The ala...

Страница 6: ...l operation Check connections before replacing the probe Temperature alarms HA and LA automatically stop as soon as the temperature returns to normal values Alarms EA and CA with ixF bAL PAL recover as soon as the digital input is disabled 18 3 OTHER MESSAGES Pon Keyboard unlocked PoF Keyboard locked noP In programming mode no parameter in Pr1 On the display or in dP2 dP3 dP4 the selected probe is...

Страница 7: ...tor fan controlled during defrost no no Pr2 Fon Evaporator fan ON time in normal mode with compressor OFF 0 0 Pr2 min FoF Evaporator fan OFF time in normal mode with compressor OFF 0 0 Pr2 min FAC Probe selection for condenser fan nP nP Pr2 St2 Set Point 2 Regulation for condenser fan 0 0 15 0 Pr2 C Hy2 Set Point 2 differential for condenser fan 1 0 10 0 Pr2 C FCC Condenser fan operating mode O_n ...

Страница 8: ...0 Pr2 hh mm Adr Serial address 1 1 Pr2 bAU Baudrate 9 6 9 6 Pr2 onC ONOFF button configuration left upper side nU nU Pr2 on2 ONOFF button timed 3sec configuration left upper side oFF oFF Pr2 LGC Light button configuration left upper side LiG LiG Pr2 LG2 Light button timed 3sec configuration left upper side nU nU Pr2 dFC DEF button configuration left upper side Pb2 Pb2 Pr2 dF2 DEF button timed 3sec...

Страница 9: ...50T150 C resolution 0 1 C or 1 C selectable Accuracy 0 7 C 1 digit and relative to the full scale Inputs 4 NTC PTC or PT1000 configurable 1 voltage free contacts I O port HOT KEY MAX voltage allowed is 5 VDC DO NOT CONNECT ANY EXTERNAL POWER SUPPLY Buzzer Optional Serial Outputs TTL standard available on 5 pin port HOT KEY connector Maximum cable length 2m Relay Outputs standard Ref Nominal UL IEC...

Отзывы: