background image

6

How to Wire

Your Ceiling Fan

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 10

Figure 11

2. Carefully lift the fan and seat the hanger ball/

downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 11). Be sure
the tab on the hanger bracket is seated in the
groove on the hanger ball (Figure 10).

1. Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connectors supplied. (Figure 12.)

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.

2. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 12). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
12). After connections have been made, separate
the white and green leads from the black and blue
leads. Carefully turn the leads upward and push
the green and white leads into one side of the
outlet box. Then push the black and blue leads into
the other side of the outlet box.

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

1. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box. (Figure 10.)

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.

WARNING

!

SUPPLY
GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY (HOT)

BLACK AND BLUE
FAN WIRES

THREADED 
STUD (2)

NOTE: CEILING COVER
OMITTED FOR CLARITY.

Figure 12

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket (Figure 12).

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 13).

5. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and installing the
two knurled knobs (supplied). (Figure 13.) Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.

U.L. Model No.: 51-OD

Содержание DEVONSHIRE CF670BQ01

Страница 1: ... the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is N...

Страница 2: ...Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must b grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50...

Страница 3: ...l Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING WARNING FAN BLADES CEILING COVER SWITCH H...

Страница 4: ...the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 2 could result in the fan falling WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are proper ly installed co...

Страница 5: ... fan You can now proceed with hanging and wiring your fan 12 Position the switch housing assembly on the switch housing plate and secure using three captive Phillips flathead screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and the switch housing plate To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support o...

Страница 6: ...ories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 1 Securely attach the hanger bracket to the outlet bo...

Страница 7: ...ll chain switch The operating sequence is as follows THREE SPEED 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF Reverse Switch Information Season Rotation Direction Reversing Switch Summer Counter Clockwise Pull Once Winter Clockwise Pull Twice 7 Using Your Ceiling Fan SPEED CONTROL SWITCH PULL CHAIN REVERSING CONTROL PULL CHAIN IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cl...

Страница 8: ... the way to one side 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Screws securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan flanges to the are loose motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against t...

Отзывы: