background image

Tools Needed for Assembly

One Phillips head screwdriver
One stepladder
One wire stripper
Two wire connectors (supplied)

MATERIALS

Wiring, outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
sizes:

2

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 5). If you feel
you do not have enough wiring knowledge or experi-
ence, have your fan installed by a licensed electrician.

WARNING

!

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED

PORCHES, COVERED PATIOS, AND COVERED DECKS...

ANYWHERE THERE IS A ROOF OVERHEAD.

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to

the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan

without blades.

2. The installation is to be in accordance with the National Electrical Code, “ANSI/NFPA 70-2008” and Local

Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must b

grounded as a precaution against possible electrical shock. Electrical installation should be made or approved

by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as “Acceptable for Fan Support of 50 lbs or less”, and use the mounting screws
provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable
for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an

8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the

fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically

approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any accessories

designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: 

To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

WARNING

!

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.

U.L. Model No.: 51-OD

Содержание DEVONSHIRE CF670BQ01

Страница 1: ... the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is N...

Страница 2: ...Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must b grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50...

Страница 3: ...l Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING WARNING FAN BLADES CEILING COVER SWITCH H...

Страница 4: ...the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 2 could result in the fan falling WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are proper ly installed co...

Страница 5: ... fan You can now proceed with hanging and wiring your fan 12 Position the switch housing assembly on the switch housing plate and secure using three captive Phillips flathead screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and the switch housing plate To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support o...

Страница 6: ...ories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 1 Securely attach the hanger bracket to the outlet bo...

Страница 7: ...ll chain switch The operating sequence is as follows THREE SPEED 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF Reverse Switch Information Season Rotation Direction Reversing Switch Summer Counter Clockwise Pull Once Winter Clockwise Pull Twice 7 Using Your Ceiling Fan SPEED CONTROL SWITCH PULL CHAIN REVERSING CONTROL PULL CHAIN IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cl...

Страница 8: ... the way to one side 2 Fan sounds noisy 1 Blades not attached to fan 1 Attach blades to fan before operating 2 Screws securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan flanges to the are loose motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against t...