100-412-183 REV. 13
131
8.6.3
Ultrasonic Power Problems
Table 8.16 Troubleshooting Ultrasonic Power Problems
Problem
Check
Solution
Ultrasonic power delivered
to horn; no indication on
bar graph.
Check connector cables,
replace if failed.
Replace defective
cables.
Test power supply.
See
No ultrasonic power
generated when Test key
pressed; no Alarm indicator.
Failed or missing stack.
Replace.
RF cable unplugged or failed;
replace if failed.
Plug in or replace.
Test power supply (see
).
If defective, send unit
for repair.
Unable to adjust amplitude
using the front panel
keypad.
Register setting configured to
“External Amplitude Control”
Reset if required, See
.
Unable to remote control.
User I/O cable
Repair or replace.
Customer’s switching device
Test/inspect/repair/
replace.
Содержание DCX S
Страница 4: ...iv 100 412 183 REV 13 ...
Страница 14: ...4 100 412 183 REV 13 Figure 1 2 Safety related Labels found on the DCX S Power Supply Vertical ...
Страница 22: ...12 100 412 183 REV 13 ...
Страница 36: ...26 100 412 183 REV 13 ...
Страница 47: ...100 412 183 REV 13 37 4 3 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Страница 50: ...40 100 412 183 REV 13 ...
Страница 54: ...44 100 412 183 REV 13 Figure 5 1 DCX S Power Supply Benchtop Dimensional Drawing ...
Страница 86: ...76 100 412 183 REV 13 ...
Страница 87: ...100 412 183 REV 13 77 Chapter 6 Converters and Boosters 6 1 Converters and Boosters 78 ...
Страница 120: ...110 100 412 183 REV 13 ...
Страница 137: ...100 412 183 REV 13 127 8 5 Circuit Diagram Figure 8 2 Interconnect Diagram Power Supply ...
Страница 144: ...134 100 412 183 REV 13 ...
Страница 145: ...100 412 183 REV 13 135 Appendix A Timing Diagrams A 1 Timing Diagrams 136 ...
Страница 146: ...136 100 412 183 REV 13 A 1 Timing Diagrams Figure A 1 Weld Cycle Figure A 2 Weld Cycle Figure A 3 Weld Cycle ...
Страница 147: ...100 412 183 REV 13 137 Appendix B Signal Diagrams B 1 Signal Diagrams 138 ...
Страница 154: ...144 100 412 183 REV 13 ...