100-412-183 REV. 13
119
8.2.3
Stud Torque Values
* Add a drop of Loctite 290 threadlocker to the stud. Torque and let cure for 30 minutes before using.
8.2.4
Routine Component Replacement
The lifetime of certain parts is based on the number of cycles the unit has completed, or
on hours of operation. Change cooling fans at 20,000 hours, and filter kits as required.
Table 8.7
Stud Torque Values
Used on
Stud Size
Torque
EDP #
20 kHz
1/2 in x 20 x 1-1/4 in
450 in·lb, 50.84 N·m
100-098-370
1/2 in x 20 x 1-1/2 in
100-098-123
30 kHz
3/8 in x 24 x 1 in
290 in·lb, 32.76 N·m
100-298-170R
40 kHz*
M8 x 1.25
70 in·lb, 7.91 N·m
100-098-790
Содержание DCX S
Страница 4: ...iv 100 412 183 REV 13 ...
Страница 14: ...4 100 412 183 REV 13 Figure 1 2 Safety related Labels found on the DCX S Power Supply Vertical ...
Страница 22: ...12 100 412 183 REV 13 ...
Страница 36: ...26 100 412 183 REV 13 ...
Страница 47: ...100 412 183 REV 13 37 4 3 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Страница 50: ...40 100 412 183 REV 13 ...
Страница 54: ...44 100 412 183 REV 13 Figure 5 1 DCX S Power Supply Benchtop Dimensional Drawing ...
Страница 86: ...76 100 412 183 REV 13 ...
Страница 87: ...100 412 183 REV 13 77 Chapter 6 Converters and Boosters 6 1 Converters and Boosters 78 ...
Страница 120: ...110 100 412 183 REV 13 ...
Страница 137: ...100 412 183 REV 13 127 8 5 Circuit Diagram Figure 8 2 Interconnect Diagram Power Supply ...
Страница 144: ...134 100 412 183 REV 13 ...
Страница 145: ...100 412 183 REV 13 135 Appendix A Timing Diagrams A 1 Timing Diagrams 136 ...
Страница 146: ...136 100 412 183 REV 13 A 1 Timing Diagrams Figure A 1 Weld Cycle Figure A 2 Weld Cycle Figure A 3 Weld Cycle ...
Страница 147: ...100 412 183 REV 13 137 Appendix B Signal Diagrams B 1 Signal Diagrams 138 ...
Страница 154: ...144 100 412 183 REV 13 ...