3.2.7
Conduit installation guidelines
WARNING!
All wiring should be installed by a trained and qualified electrician. Wiring must conform to all
applicable local codes and regulations.
•
Adhere to IEEE 1100 specifications for grounding.
•
Do not exceed a 40 percent fill for conduits.
•
Route the conduit away from power trays using these guidelines:
6 in.
110 VAC
12 in.
220 VAC
24 in.
440 VAC
•
Attach the conduit to the NPT threaded holes on the side of the CSI 9420.
3.2.8
Connect the sensors
WARNING!
If the sensor is installed in a high-voltage environment and a fault condition or installation
error occurs, the sensor leads and transmitter terminals could carry lethal voltages. Use
extreme caution when making contact with the leads and terminals.
Procedure
1.
Remove the transmitter back cover.
2.
Attach the sensor leads. Follow the wiring diagram in
sensor, the wiring diagram in
to connect two sensors, and the wiring
diagram in
to connect one sensor with temperature.
Note
You can connect one or two accelerometers to the CSI 9420. You can connect only one
accelerometer with a temperature sensor.
Setup
78
MHM-97408, Rev 15
Содержание CSI 9420
Страница 4: ......
Страница 10: ...Revision numbers in AMS Device Manager Figure 1 2 Introduction 4 MHM 97408 Rev 15 ...
Страница 60: ...PeakVue spectrum Figure 2 35 Configuration 54 MHM 97408 Rev 15 ...
Страница 92: ...Setup 86 MHM 97408 Rev 15 ...
Страница 98: ...Velocity waveform Figure 5 1 PeakVue waveform Figure 5 2 Velocity PeakVue and temperature 92 MHM 97408 Rev 15 ...
Страница 134: ...Product certifications 128 MHM 97408 Rev 15 ...
Страница 144: ...LCD screen messages 138 MHM 97408 Rev 15 ...