Fault
Action to Reset
Bridge Disabled
Watchdog timer
Button
Yes
.l.
Power-up self test failure
Power
Yes
Non-volatile memory invalid
Button
Yes
I
I..)
Invalid configuration
Power
Yes
Power stage fault
Button
Yes
High DC bus fault
Button
Yes
Low DC bus fault
Button
Yes
Encoder State
Power
Yes
f E n c o d e r line fault
Power
Yes
Motor over temperature fault
Button
Yes
EMS shunt power fault
Button
Yes
El
Over speed fault
Button
Yes
Following error fault (position
mode)
Button
Yes
CW/CCW limit (velocity or Torque)
Auto
No
The drive accurately tracks rotor position during fault conditions. For example,
i f there is a "Low DC Bus" fault where the bridge is disabled, the drive will
continue to track the rotor's position provided the logic power is not
interrupted.
The CW/CCW Limit faults are automatically cleared when the fault condition
is removed. The table below lists all the fault codes in priority order from
highest to lowest. This means that if two faults are active, the higher priority
fault will be displayed.
Table 11
D i s p l a y Fault Codes
58
Содержание Control Techniques EN-204
Страница 2: ...ESeries Drives Basic Installation Manual LiMIERS N M O T I O N C O N T R O L ...
Страница 8: ...ESeries Drives Basic Installation Manual vi ...
Страница 12: ......
Страница 54: ...EN Series Drives Manual 42 ...
Страница 68: ...EN Series Drives Manual 56 ...
Страница 74: ...EN Series Drives Manual 62 ...
Страница 82: ...EN Series Drives Manual 70 ...
Страница 86: ......
Страница 87: ......