4. Attach one blade assembly to the motor using two

1/4-20 x 1/2” phillips head blade flange screws
(Figure 8). Make sure the screws are tightened
securely. Repeat this procedure for the other four
blade assemblies.

NOTE: Take care not to scratch the fan housing
when installing the blade assemblies.

5. Engage the color-coded connector of the switch

housing/light fitter with the motor connector (Figure
9). Match the color stripes on the two connectors
and push together until fully seated and latched.

6. Position the switch housing/light fitter on the switch

housing plate and align the holes in the switch
housing/light fitter with the holes in the plate.
Secure by installing three 5/32 x 1/4" screws
(Figure 10).

CRYSTAL
GLASS
HOUSING

1/4-20 x 1/2"
PHILLIPS HEAD SCREWS

FAN BLADE

FLANGE 
ASSEMBLY

Figure 8

7. Back out the three thumb screws in one shade

holder until the shade neck slips into the holder.
Then tighten the thumb screws until they touch the
neck with approximate equal projection on the out-
side (Figure 11). Repeat for the other three shades.
Never use pliers to tighten the thumb screws or a
broken or damaged shade may result.

MOTOR CONNECTOR

SWITCH HOUSING/
LIGHT FITTER CONNECTOR

MOTOR

CONNECTOR

SWITCH  HOUSING/

LIGHT FITTER

CONNECTOR

LATCH

Figure 9

5/32 x 1/4"
SCREWS (3)

SWITCH
HOUSING
PLATE

SWITCH HOUSING/
LIGHT FITTER

Figure 10

HOLDER

GLASS SHADE

KNURLED
SCREW
(3 PER
SHADE)

Figure 11

Replacement of Light Bulbs

To replace the 60-watt (maximum) intermediate base
light bulbs in the light kit, turn off the electricity at the
wall switch and simply unscrew the bulbs from the
sockets and screw in new ones.

To replace the 7-watt (maximum) candelabra base
light bulbs in the crystal glass housing, first turn off
the electricity at the main fuse box or circuit breaker
panel. Remove the switch housing/light fitter and

disconnect the connector. Remove the five fan
blades, then loosen the two screws at the two keyhole
slots at the top of the crystal glass housing and
remove the two screws at the two slotted holes. Turn
the crystal glass housing to the left and carefully
remove the housing. Replace the burned out 7-watt
candelbra base bulbs and then install the crystal glass
housing, the five fan blades, and the switch
housing/light fitter.

MOTOR

CONNECTOR

SWITCH HOUSING/

LIGHT FITTER

CONNECTOR

Periodically check the tightness of the tightness of
the knurled screws. Fan operation may loosen these
screws, causing the shade to fall out.

WARNING

!

To avoid possible fire or shock, do not pinch wire
between the switch housing light fitter and the plate.

WARNING

!

To avoid fire hazard, use 60-watt or less rated
intermediate base bulbs.

WARNING

!

Содержание CF875

Страница 1: ...horized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass g...

Страница 2: ...e only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ce...

Страница 3: ...r fan installed by a licensed electrician WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces sories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Do not install or...

Страница 4: ...HOW TO PUT YOUR CEILING FAN TOGETHER MOTOR MOTOR BRACKET SUPPLY WIRE LEADS THREADED STUDS 4 HOOK MOUNTING PLATE LIGHT FITTER Figure 3 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may ne...

Страница 5: ...four 7 watt 120 volt light bulbs into the sock ets on the mounting plate light fitter 2 Install two 3 16 24 x 3 8 screws several turns into screw holes on opposite sides of the mounting plate light fitter Figure 6 Position the crystal glass housing so that the keyhole slots in the crystal glass housing engage with the two screws Turn the housing to the right so the keyhole slots rest on the screws...

Страница 6: ... LIGHT FITTER CONNECTOR LATCH Figure 9 5 32 x 1 4 SCREWS 3 SWITCH HOUSING PLATE SWITCH HOUSING LIGHT FITTER Figure 10 HOLDER GLASS SHADE KNURLED SCREW 3 PER SHADE Figure 11 Replacement of Light Bulbs To replace the 60 watt maximum intermediate base light bulbs in the light kit turn off the electricity at the wall switch and simply unscrew the bulbs from the sockets and screw in new ones To replace...

Страница 7: ...ounting plate light fitter and or ceiling 3 Tighten the mounting plate light fitter outlet box are not securely fastened screws to the outlet box and or secure outlet box 4 Fan blades out of balance 4 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Maintenance IMPORTANT CARE INSTRUCTIONS For Your Ceiling Fan Periodic cleaning of your n...

Страница 8: ...G INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 To reduce the risk of fire or electrical shock do not use fan with any solid state speed control device WARNING This product is designed to use only those parts supplied with this product and or any accessories ...

Отзывы: