background image

2

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to

the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan

without blades.

2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and Local Electrical

Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a
precaution against possible electrical shock. Electrical installation should be made or approved by a licensed
electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.

4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an

8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the

fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically

approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any accessories

designated specifically for use this product by Emerson Electric Co. could result in personal injury or property
damage.

WARNING: 

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: 

To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.

WARNING

!

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep it

in a safe place for future use.

Содержание CF875

Страница 1: ...horized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass g...

Страница 2: ...e only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ce...

Страница 3: ...r fan installed by a licensed electrician WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces sories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Do not install or...

Страница 4: ...HOW TO PUT YOUR CEILING FAN TOGETHER MOTOR MOTOR BRACKET SUPPLY WIRE LEADS THREADED STUDS 4 HOOK MOUNTING PLATE LIGHT FITTER Figure 3 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may ne...

Страница 5: ...four 7 watt 120 volt light bulbs into the sock ets on the mounting plate light fitter 2 Install two 3 16 24 x 3 8 screws several turns into screw holes on opposite sides of the mounting plate light fitter Figure 6 Position the crystal glass housing so that the keyhole slots in the crystal glass housing engage with the two screws Turn the housing to the right so the keyhole slots rest on the screws...

Страница 6: ... LIGHT FITTER CONNECTOR LATCH Figure 9 5 32 x 1 4 SCREWS 3 SWITCH HOUSING PLATE SWITCH HOUSING LIGHT FITTER Figure 10 HOLDER GLASS SHADE KNURLED SCREW 3 PER SHADE Figure 11 Replacement of Light Bulbs To replace the 60 watt maximum intermediate base light bulbs in the light kit turn off the electricity at the wall switch and simply unscrew the bulbs from the sockets and screw in new ones To replace...

Страница 7: ...ounting plate light fitter and or ceiling 3 Tighten the mounting plate light fitter outlet box are not securely fastened screws to the outlet box and or secure outlet box 4 Fan blades out of balance 4 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Maintenance IMPORTANT CARE INSTRUCTIONS For Your Ceiling Fan Periodic cleaning of your n...

Страница 8: ...G INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 To reduce the risk of fire or electrical shock do not use fan with any solid state speed control device WARNING This product is designed to use only those parts supplied with this product and or any accessories ...

Отзывы: