manualshive.com logo in svg
background image

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.

Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation) (Figure 10). Securely connect wires
using wire connectors supplied.

NOTE: When wiring the ceiling fan for close-to-
the-ceiling mounting, there will be no green
grounding lead from the hanger ball.

Wiring The Ceiling Fan

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

WARNING

!

Electrical Requirements

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local Codes and the ceiling fan must be properly
grounded as a precaution against possible
electrical shock.

WARNING

!

Hanging The Ceiling Fan

(Close-to-the-Ceiling Method with

Ceiling Cover Installed on

the Motor Housing)

1.

Carefully lift the fan assembly up to the hanger
bracket. Pass the hook on the hanger bracket
(Figure 8) through one of the screw holes (not the
slots) in the ceiling cover (Figure 9). The hook
must pass from the inside of the ceiling cover to
the outside. The hook will hold the fan assembly
while connecting the wiring.

The hook must pass through the screw hole in the
ceiling cover from the inside to the outside. Any
other hanging method may cause the hook to break
and the fan to fall.

WARNING

!

CEILING
COVER

HOOK ON HANGER BRACKET MUST PASS THROUGH SCREW  HOLE 
IN CEILING COVER, INSIDE OF BRACKET TO OUTSIDE OF  BRACKET

HANGER
BRACKET

HOOK

TAB

GROOVE

HANGER
BALL

Figure 8

To reduce the risk of fire, electrical shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support”, and use screws supplied with outlet box.
Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

To avoid fire or shock, do not pinch wires between
the hanger ball/downrod assembly and hanger
bracket.

WARNING

!

WARNING

!

Hanging The Ceiling Fan

(Standard Method Using

Hanger Ball/Downrod)

1.

Carefully lift the fan assembly and seat the hanger
ball in the hanger bracket (Figure 8). The tab on
the hanger bracket must seat in the groove in the
hanger ball.

NOTE: CEILING COVER, SUPPLY
WIRES AND FAN WIRES OMITTED
FOR CLARITY.

Содержание CF713BS00

Страница 1: ...rt No F40BP74200002 Form No BP7420 2 ETL Model No CF713 READ AND SAVE THESE INSTRUCTIONS PRO Series Energy Star Ceiling Fan Owner s Manual Net Weight 19 0 Lbs Model Numbers CF713BS00 CF713ORB00 CF713WW00 ...

Страница 2: ...es listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Страница 3: ...ck off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan insta...

Страница 4: ...lose to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case should the fan blades be lower than seven feet above the floor...

Страница 5: ...be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING Installing The Hanger Bracket Installing The Ceiling Cover On The Fan Motor Housing For Close to the Ceiling Mounting 1 Remove and retain three screws from the top of the motor housing Figure 3A 2 Position the rubber gasket supplied in parts bag on the motor housing ...

Страница 6: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 8 through one of the screw holes not the slots in the ceiling cover Figure 9 The hook must pass f...

Страница 7: ...e rubber grommets are firmly seated on each of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 12 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 10 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector s...

Страница 8: ...he motor hub by mating the alignment post Figure 12 of the flange with one of the alignment slots in the motor hub Figure 13 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other four blade assemblies Make sure all screws are tightened 5 Attach the switch housing cover with light fitter to the switch housing using the three prev...

Страница 9: ... the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 10 Install pendants onto light fixture chain and fan switch chain using couplings provided NOTE It is advisable to periodically check the tightness of the finial IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that ...

Страница 10: ...r coupling are loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure th...

Страница 11: ...t authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warran...

Страница 12: ...4 Pendant Light 15 Screw M5 x 6 Washer Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket 18 Finial Nut 762892 3 762892 1 762892 6 19 Outer Bowl Cap 762891 3 762891 1 762891 6 20 Fuse 1 25A 125W 763744 763744 763744 Owner s Manual BP7420 2 BP7420 2 BP7420 2 Repair Parts Listing Form No BP7420 2 Part No F40BP74200002 Printed in China 06 10 Air Comfort Products DIVISION OF EMERSON ELECTR...