Installing The Hanger

Ball/Downrod Assembly

(For Standard Mounting)

1.

Pass the 42" motor leads through the opening in
the ceiling cover. Be sure the cover is oriented
correctly.

2.

Separate, untwist and unkink the three motor
leads. Route the motor leads through the hanger
ball/downrod assembly.

3.

Loosen the two setscrews in the motor coupling.
Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 2). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the hanger ball to make sure the clevis pin is
properly installed.

HANGER 
BALL/DOWNROD 
ASSEMBLY

CEILING 
COVER

SETSCREW

CLEVIS
PIN

HAIRPIN
CLIP

DECORATIVE
CAP

SETSCREW

MOTOR COUPLING

Figure 2

REMOVE AND RETAIN
TWO SCREWS AND LOCKWASHERS

LOOSEN THE TWO SCREWS 
IN THE KEYHOLE SLOTS

CEILING 
COVER

HANGER 
BRACKET

Figure 1

IMPORTANT

Your ceiling fan is designed to be installed
either in the standard manner, or in the
close-to-the-ceiling manner. Using the
standard method, the hanger ball/downrod
assembly will suspend the fan several inches
below the ceiling cover. Using the
close-to-the-ceiling method, the ceiling cover
installs directly on the fan motor housing,
thus mounting the fan 3-1/2 inches closer to
the ceiling than the standard method. In no
case should the fan blades be lower than
seven feet above the floor. Depending on
your desired mounting method, proceed to
“INSTALLING HANGER BALL/DOWNROD
ASSEMBLY” for standard mounting, or to
“INSTALLING CEILING COVER ON FAN
MOTOR HOUSING” for close-to-the-ceiling
mounting.

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

4.

While pulling up on the hanger ball, securely
tighten the two setscrews in the motor coupling
(Figure 2).

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

5.

The fan comes with blue, black and white leads that
are 42” long. Measure up approximately
6 to 9-inches above top of hanger ball/downrod
assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.

1.

Loosen the two screws in the keyholes slots of the
ceiling cover. Remove and retain the other two
screws and lockwashers (Figure 1).

2.

Turn the ceiling cover and remove the hanger
bracket.

Removal Of The

Hanger Bracket

Содержание CF713BS00

Страница 1: ...rt No F40BP74200002 Form No BP7420 2 ETL Model No CF713 READ AND SAVE THESE INSTRUCTIONS PRO Series Energy Star Ceiling Fan Owner s Manual Net Weight 19 0 Lbs Model Numbers CF713BS00 CF713ORB00 CF713WW00 ...

Страница 2: ...es listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Страница 3: ...ck off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan insta...

Страница 4: ...lose to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case should the fan blades be lower than seven feet above the floor...

Страница 5: ...be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING Installing The Hanger Bracket Installing The Ceiling Cover On The Fan Motor Housing For Close to the Ceiling Mounting 1 Remove and retain three screws from the top of the motor housing Figure 3A 2 Position the rubber gasket supplied in parts bag on the motor housing ...

Страница 6: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 8 through one of the screw holes not the slots in the ceiling cover Figure 9 The hook must pass f...

Страница 7: ...e rubber grommets are firmly seated on each of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 12 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 10 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector s...

Страница 8: ...he motor hub by mating the alignment post Figure 12 of the flange with one of the alignment slots in the motor hub Figure 13 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other four blade assemblies Make sure all screws are tightened 5 Attach the switch housing cover with light fitter to the switch housing using the three prev...

Страница 9: ... the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 10 Install pendants onto light fixture chain and fan switch chain using couplings provided NOTE It is advisable to periodically check the tightness of the finial IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that ...

Страница 10: ...r coupling are loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure th...

Страница 11: ...t authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warran...

Страница 12: ...4 Pendant Light 15 Screw M5 x 6 Washer Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket 18 Finial Nut 762892 3 762892 1 762892 6 19 Outer Bowl Cap 762891 3 762891 1 762891 6 20 Fuse 1 25A 125W 763744 763744 763744 Owner s Manual BP7420 2 BP7420 2 BP7420 2 Repair Parts Listing Form No BP7420 2 Part No F40BP74200002 Printed in China 06 10 Air Comfort Products DIVISION OF EMERSON ELECTR...

Отзывы: