background image

WARNING:

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to

the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan

without blades.

2. The installation is to be in accordance with the National Electrical Code, “ANSI/NFPA 70-2008” and Local

Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical shock. Electrical installation should be made or approved
by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.

4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an

8-foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the

fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE:

This fan is suitable for use with solid-state speed controls.

WARNING:

This product is designed to use only those parts supplied with this product and/or any accessories

designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING:

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING:

To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

WARNING

!

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep

it in a safe place for future use.

Содержание CF713BS00

Страница 1: ...rt No F40BP74200002 Form No BP7420 2 ETL Model No CF713 READ AND SAVE THESE INSTRUCTIONS PRO Series Energy Star Ceiling Fan Owner s Manual Net Weight 19 0 Lbs Model Numbers CF713BS00 CF713ORB00 CF713WW00 ...

Страница 2: ...es listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Страница 3: ...ck off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan insta...

Страница 4: ...lose to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case should the fan blades be lower than seven feet above the floor...

Страница 5: ...be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING Installing The Hanger Bracket Installing The Ceiling Cover On The Fan Motor Housing For Close to the Ceiling Mounting 1 Remove and retain three screws from the top of the motor housing Figure 3A 2 Position the rubber gasket supplied in parts bag on the motor housing ...

Страница 6: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 8 through one of the screw holes not the slots in the ceiling cover Figure 9 The hook must pass f...

Страница 7: ...e rubber grommets are firmly seated on each of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 12 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 10 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector s...

Страница 8: ...he motor hub by mating the alignment post Figure 12 of the flange with one of the alignment slots in the motor hub Figure 13 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other four blade assemblies Make sure all screws are tightened 5 Attach the switch housing cover with light fitter to the switch housing using the three prev...

Страница 9: ... the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 10 Install pendants onto light fixture chain and fan switch chain using couplings provided NOTE It is advisable to periodically check the tightness of the finial IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that ...

Страница 10: ...r coupling are loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure th...

Страница 11: ...t authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warran...

Страница 12: ...4 Pendant Light 15 Screw M5 x 6 Washer Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket 18 Finial Nut 762892 3 762892 1 762892 6 19 Outer Bowl Cap 762891 3 762891 1 762891 6 20 Fuse 1 25A 125W 763744 763744 763744 Owner s Manual BP7420 2 BP7420 2 BP7420 2 Repair Parts Listing Form No BP7420 2 Part No F40BP74200002 Printed in China 06 10 Air Comfort Products DIVISION OF EMERSON ELECTR...

Отзывы: