Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit breakers.

WARNING:

Make sure main power is turned off.

2. Loose power line connections to the fan, or loose 

2. Check line wire connections to fan and switch wire 

switch wire connections in the switch housing.

connections in the switch housing.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way to one 

side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Screws securing fan blade flanges to motor hub 

2. Check to make sure the screws which attach the fan

are loose.

flanges to the motor hub are tight. 

WARNING:

Make sure main power is turned off.

3. Wire connectors inside switch housing rattling.

3. Check to make sure wire connectors in switch housing

are not rattling against each other or against the interior
wall of the switch housing.

4. Motor noise caused by solid-state variable

4. Some fan motors are sensitive to signals from Solid-

speed control.

State variable speed controls. If Solid-State Control
is used and motor noise results choose an alternative
control method.

5. Screws holding blades to flanges are loose.

5. Tighten screws securely.

3. Fan wobbles

1. Setscrews in motor coupling are loose.

1. Tighten both setscrews securely in the motor coupling.

excessively.

2. Setscrew in hanger ball/downrod assembly is

2. Tighten the setscrew in the hanger ball/downrod

loose.

assembly.

3. Screws securing fan blade flanges to motor are

3. Check to be sure screws which attach the fan blade

loose.

flanges to the motor are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and

uniformly to the surface of the motor. 

5. Hanger bracket and/or ceiling outlet box is not    

5. Tighten the hanger bracket screws to the outlet box,

securely fastened.

and/or secure outlet box. 

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can 

redistribute the weight and result in smoother operation.

4. All three lamps will not

illuminate.

WARNING: 

Make sure main power is turned off.

1. The 1.25 amp lamp fuse may have blown and

1. Replace the 1.25 amp fuse with Emerson repair part

and needs replacement.

item 20. See page 8 and reverse the switch housing
installation instructions to gain access to the fuse holder.

WARNING: 

Over lamping the light kit will result 

a blown fuse. Before replacing the fuse, shut off the
electrical supply at the main fuse box or circuit
breaker panel. The fuse is located in the light box.
Replacement fuse shall be rated 125V, 1.25A.
Restore electrical power to the light kit at the main
fuse box or circuit breaker panel.

WARNING:

For your own safety, turn off power at fuse box or circuit breaker before trouble

shooting your fan.

!

!

!

!

!

Содержание CF713BS00

Страница 1: ...rt No F40BP74200002 Form No BP7420 2 ETL Model No CF713 READ AND SAVE THESE INSTRUCTIONS PRO Series Energy Star Ceiling Fan Owner s Manual Net Weight 19 0 Lbs Model Numbers CF713BS00 CF713ORB00 CF713WW00 ...

Страница 2: ...es listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Страница 3: ...ck off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan insta...

Страница 4: ...lose to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case should the fan blades be lower than seven feet above the floor...

Страница 5: ...be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING Installing The Hanger Bracket Installing The Ceiling Cover On The Fan Motor Housing For Close to the Ceiling Mounting 1 Remove and retain three screws from the top of the motor housing Figure 3A 2 Position the rubber gasket supplied in parts bag on the motor housing ...

Страница 6: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 8 through one of the screw holes not the slots in the ceiling cover Figure 9 The hook must pass f...

Страница 7: ...e rubber grommets are firmly seated on each of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 12 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 10 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector s...

Страница 8: ...he motor hub by mating the alignment post Figure 12 of the flange with one of the alignment slots in the motor hub Figure 13 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other four blade assemblies Make sure all screws are tightened 5 Attach the switch housing cover with light fitter to the switch housing using the three prev...

Страница 9: ... the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs 10 Install pendants onto light fixture chain and fan switch chain using couplings provided NOTE It is advisable to periodically check the tightness of the finial IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that ...

Страница 10: ...r coupling are loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure th...

Страница 11: ...t authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warran...

Страница 12: ...4 Pendant Light 15 Screw M5 x 6 Washer Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket 18 Finial Nut 762892 3 762892 1 762892 6 19 Outer Bowl Cap 762891 3 762891 1 762891 6 20 Fuse 1 25A 125W 763744 763744 763744 Owner s Manual BP7420 2 BP7420 2 BP7420 2 Repair Parts Listing Form No BP7420 2 Part No F40BP74200002 Printed in China 06 10 Air Comfort Products DIVISION OF EMERSON ELECTR...