10
Setting Operating
Frequency of Wall Control
and Receiver
(Figure 19)
Your wall control and receiver have code switches
which must be set in one of 16 possible code combi-
nations. The four levers (numbered 1, 2, 3, and 4) on
the switches are factory-set in the ON (up) position.
Change the switch settings as follows:
1.
Slide the four switch levers in the wall control to
your choice of ON (up) or down positions. Use a
ball-point pen or small screwdriver and slide the
levers firmly up or down.
2.
In the receiver, slide the four switch levers to the
same positions as set in the wall control. Make
sure the levers on both switches are in the same
positions, otherwise the fan will not operate.
ON
1
2
3
4
WALL CONTROL
LEVERS
CODE
SWITCH
SW105
RECEIVER
CODE
SWITCH
SW114 WALL
CONTROL
ON
1
2
3
4
RECEIVER SWITCH
LEVERS
HI
HI
MED
MED
LOW
LOW
FAN OFF
REV
REV
LIGHT
Figure 19
The SW114 wall control transmits the command
signals via radio waves to the SW105 receiver
installed in the ceiling fan ceiling cover. The
SW105 receiver is required for the SW114 wall
control to function. Power for the SW114 wall
control comes from the 12V battery, located in the
wall control.
Replacement 12V batteries recommended are
Duracell MN21 and Eveready A23.
1.
Install the 12V battery (supplied) into the wall
control (Figure 20).
2.
The SW114 wall control is supplied with a white,
ivory or almond color cover. Choose the style that
best suits your needs and snap the cover onto the
wall control (Figure 20).
12V BATTERY
WALL
CONTROL
COVER
SW114 WALL
CONTROL
HI
HI
MED
MED
LOW
LOW
FAN OFF
REV
REV
LIGHT
Figure 20
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box.
WARNING
!
Installation
of Wall Control
3.
Install the wall control onto the outlet box using the
supplied screws (Figure 21).
4.
Install decorator wall plate (not included) using the
two screws provided with wall plate (Figure 21).
SW114 WALL
CONTROL
DECORATIVE WALL
PLATE (Not Included)
OUTLET
BOX
WALL PLATE
SCREW (2)
WALL CONTROL
SCREW (2)
REV
HI
MED
LOW
FAN OFF
LIGHT
Figure 21
Ceiling Fan Procedures
General
Your Emerson Ceiling Fan/Light Wall Control consists
of a wall mount transmitter. The SW114 transmitter
works in conjunction with the SW105 Receiver
(purchased separately). The receiver is mounted
under the fan ceiling cover. The wall control is
designed to separately control your ceiling fan speed,
direction, uplight and downlight intensity.
Code switches in the wall control and receiver may be
set in 16 different positions. If your fan and light go on
and off without using your control, you may be getting
interference from other transmitters such as garage
door openers, car alarms or security systems.
To remedy this situation, simply change the combina-
tion code in your wall control and receiver.
U.L. Model No.: CF3000