background image

2

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel

disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off

the power to the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not

operate fan without blades.

2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local

Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical
shock. Electrical installation should be made or approved by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50

pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 50 lbs or less”, and use
the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of
light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.

4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance

for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental

contact with the fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not

know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not

specifically approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any

accessories designated specifically for use with this product by Emerson Company. Substitution of
parts or accessories not designated for use with this product by Emerson Company could result in
personal injury or property damage.

WARNING: 

To Reduce the risk of personal injury, do not bend the blade flange when installing the

blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.

WARNING

!

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep

it in a safe place for future use.

Содержание CF2800BS

Страница 1: ...rized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass glo...

Страница 2: ...d as Acceptable for Fan Support of 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The...

Страница 3: ...d studs 5 Two 1 1 4 threaded studs 6 Four knurled knobs 7 Four lockwashers 3 8 Three wire connectors 9 Two pull chain pendants 10 Two plastic couplings 11 One hairpin clip 12 One clevis pin 13 Eleven 10 32 x 1 oval head screws 14 Thirty two 10 32 x 8mm Phillips button head screws 15 Forty two 6 32 x 6mm Phillips button head screws 16 One fiber washer 17 Two 8 32 x 3 8 pan head screws NOTE Place th...

Страница 4: ...screw using the setscrew wrench supplied NOTE The setscrews must be properly installed as described above or fan wobble could result 6 Screw two 1 threaded studs supplied into the motor Figure 3 Leave approximately 7 8 of the stud extending above the motor Coil the wires and wire connectors around the motor coupling then slide the motor cover over the downrod and rotate the cover until the threade...

Страница 5: ...r ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 9 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads IMPORTANT When instal...

Страница 6: ...fan with the light fixture omit steps 19 through 23 and proceed to step 24 19 Remove the nut and lockwasher securing the light fixture to the switch housing cover Figure 12 Unscrew the light fixture from the switch housing cover Retain the light fixture in case you want to install it later 20 Screw the 2 1 4 pipe nipple supplied several full turns into the switch housing cover Figure 13 Reinstall ...

Страница 7: ...over Turn the switch housing cover clockwise to engage the slots then securely tighten the two screws Figure 16 NOTE Be sure the wires are not pinched between the switch housing and the switch housing cover Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling...

Страница 8: ...push the black and blue leads into the other side of the outlet box THREADED STUD 2 HANGER BRACKET WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET LISTED WIRE CONNECTOR 3 SUPPLY GROUND WIRE GREEN WIRE GROUND FROM HANGER BALL BLACK FAN WIRE BLUE FAN WIRE BLACK SUPPLY HOT WHITE FAN WIRE Figure 20 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs U...

Страница 9: ... and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch 6 Screw three candelabra base lamps 60 watt each max in the light fixture sockets Pass the light fixture switch chain through the light fixture glass Figure 22 Position the glass on the light fixture so that the three elongated points of the glass are over the three lamps In...

Страница 10: ...4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to Step 17 and Figure 11 5 Hanger bracket and or ceiling outlet box is 5 Tighten the hanger bracket screws to the outlet box and or not securely fastened secure outlet box 6 Fan blades out of balance 6 Interchanging an adj...

Страница 11: ...9 38 38 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Страница 12: ...66 762466 762466 26 Motor 762304 762304 762304 27 Hub Assembly 762487 762487 762487 28 Washer 9 16 29 Lockwasher 9 16 30 Switch Housing Assembly 762113 11 762113 12 762113 13 31 Wiring Harness Assembly 762090 5 762090 5 762090 6 32 Cover Switch Housing 762425 762425 1 762425 2 33 Light Fixture Assembly 762419 762419 762419 1 34 Glass Light Fixture 762420 762420 762420 35 Cover Plate 762424 762424 ...

Отзывы: