Tools Needed for Assembly

One Phillips head screwdriver

One wire stripper

One stepladder

Masking tape

Three wire connectors (supplied)

MATERIALS

Wiring, outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
sizes:

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is
completed, place a check mark in the box. This will insure that all steps have been
completed and will be helpful in finding your place should you be interrupted.

1. Open styrofoam unit containing fan. Remove top

half of styrofoam unit. Remove parts and check to
see that you have received the following parts:

NOTE: If you are uncertain of part description,
refer to exploded view illustration.

a. Fan motor and housing assembly
b. One motor cover
c. Once ceiling cover
d. Ten fan blades
e. Five upper blade flanges
f. Five lower blade flanges
g. Ten struts
h. One hanger ball/downrod assembly
i. One hanger bracket
j. One switch housing cover/light fixture assembly
k. One cover plate
l. One light fixture glass
m.One finial nut
n. One loose parts bag containing:

1. One 5/16-18 x 1/4” setscrew
2. One setscrew wrench
3. One 2-1/4” pipe nipple
4. Two 1” threaded studs
5. Two 1-1/4” threaded studs
6. Four knurled knobs
7. Four lockwashers

3

8. Three wire connectors
9. Two pull chain pendants

10. Two plastic couplings
11. One hairpin clip
12. One clevis pin
13. Eleven 10-32 x 1” oval head screws
14. Thirty-two 10-32 x 8mm 

Phillips button head screws

15. Forty-two 6-32 x 6mm

Phillips button head screws

16. One fiber washer
17. Two 8-32 x 3/8” pan head screws

NOTE: Place the parts from the loose parts bags in a
small container to keep them from being lost. If any
parts are missing, contact your local retailer or
catalog outlet for replacement before proceeding.

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 8). If you feel
you do not have enough wiring knowledge or experi-
ence, have your fan installed by a licensed electrician.

WARNING

!

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.

WARNING

!

WARNING

!

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

A

J

E

D

C

F

B

N

K

I

L

H

G

M

Содержание CF2800BS

Страница 1: ...rized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass glo...

Страница 2: ...d as Acceptable for Fan Support of 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The...

Страница 3: ...d studs 5 Two 1 1 4 threaded studs 6 Four knurled knobs 7 Four lockwashers 3 8 Three wire connectors 9 Two pull chain pendants 10 Two plastic couplings 11 One hairpin clip 12 One clevis pin 13 Eleven 10 32 x 1 oval head screws 14 Thirty two 10 32 x 8mm Phillips button head screws 15 Forty two 6 32 x 6mm Phillips button head screws 16 One fiber washer 17 Two 8 32 x 3 8 pan head screws NOTE Place th...

Страница 4: ...screw using the setscrew wrench supplied NOTE The setscrews must be properly installed as described above or fan wobble could result 6 Screw two 1 threaded studs supplied into the motor Figure 3 Leave approximately 7 8 of the stud extending above the motor Coil the wires and wire connectors around the motor coupling then slide the motor cover over the downrod and rotate the cover until the threade...

Страница 5: ...r ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 9 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads IMPORTANT When instal...

Страница 6: ...fan with the light fixture omit steps 19 through 23 and proceed to step 24 19 Remove the nut and lockwasher securing the light fixture to the switch housing cover Figure 12 Unscrew the light fixture from the switch housing cover Retain the light fixture in case you want to install it later 20 Screw the 2 1 4 pipe nipple supplied several full turns into the switch housing cover Figure 13 Reinstall ...

Страница 7: ...over Turn the switch housing cover clockwise to engage the slots then securely tighten the two screws Figure 16 NOTE Be sure the wires are not pinched between the switch housing and the switch housing cover Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling...

Страница 8: ...push the black and blue leads into the other side of the outlet box THREADED STUD 2 HANGER BRACKET WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET LISTED WIRE CONNECTOR 3 SUPPLY GROUND WIRE GREEN WIRE GROUND FROM HANGER BALL BLACK FAN WIRE BLUE FAN WIRE BLACK SUPPLY HOT WHITE FAN WIRE Figure 20 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs U...

Страница 9: ... and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch 6 Screw three candelabra base lamps 60 watt each max in the light fixture sockets Pass the light fixture switch chain through the light fixture glass Figure 22 Position the glass on the light fixture so that the three elongated points of the glass are over the three lamps In...

Страница 10: ...4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to Step 17 and Figure 11 5 Hanger bracket and or ceiling outlet box is 5 Tighten the hanger bracket screws to the outlet box and or not securely fastened secure outlet box 6 Fan blades out of balance 6 Interchanging an adj...

Страница 11: ...9 38 38 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Страница 12: ...66 762466 762466 26 Motor 762304 762304 762304 27 Hub Assembly 762487 762487 762487 28 Washer 9 16 29 Lockwasher 9 16 30 Switch Housing Assembly 762113 11 762113 12 762113 13 31 Wiring Harness Assembly 762090 5 762090 5 762090 6 32 Cover Switch Housing 762425 762425 1 762425 2 33 Light Fixture Assembly 762419 762419 762419 1 34 Glass Light Fixture 762420 762420 762420 35 Cover Plate 762424 762424 ...

Отзывы: