104
100-214-251 REV. 05
Error 16
x
ULS Lost Waiting for TRS Latchable - After the ULS input
became inactive, the ULS input became active again before
the TRS input became active.
Error 17
x
LLS Function Latchable - The LLS input met the conditions for
an LLS error as defined by the LLS control DIP switches. For
further information, refer to
Selecting DIP Switches.
Error 18
x
Power Supply Module Startup Overload Latchable - The SPM/
AT (System Protection Monitor) indicated a power supply
overload within the first 50 ms of operation.
Error 19
x
x
Power Supply Module Overload Error Latchable - The AUPS
indicated a power supply module overload within the first 60
ms of operation.
Error 20
x
NOVRAM Data Latchable - The data read from non-volatile
memory did not pass a data integrity check. If the power
supply cannot read the parameter settings stored in NOVRAM
at power-up, the factory-set settings are used.
Error 21
x
x
SV Active Error Non-Resettable - The SV drive output did not
meet the requirements for activating the SV. This error
cannot be cleared by RESET, or by the external RESET input.
Error 23
x
ULS Lost Waiting for TRS Latchable - After the ULS input
became inactive, the ULS input became active again before
the PTS input became active (PTS enabled).
Error 24
x
PTS Lost Waiting for TRS Latchable - After the PTS input
became active, the PTS input became inactive again before
the TRS input became active.
Error 25
x
SV Deactive Error Non-Resettable - The SV drive output did
not meet the requirements for deactivating the solenoid
valve. This error cannot be cleared by RESET, or by the
external RESET input.
Error 26
x
START SWITCH 2 Lost Non-Latching - START SWITCH 2 was
lost before the trigger became active.
Error 27
x
SV Safety Error Non-Resettable - SV drive safety circuit is not
working. This error cannot be cleared by RESET, or by the
external RESET input.
Error 28
x
START SWITCH 2 Stagger Error Non-Latching -START
SWITCH 2 was not pressed within 200 ms after START
SWITCH 1 was pressed.
Error 29
x
START SWITCH 1 Stagger Error Non-Latching - START
SWITCH 1 was not pressed within 200 ms after START
SWITCH 2 was pressed.
Error 30
x
Time Limit Error Latchable - Minus time limit not reached.
Table 6.11 Error Codes
Error
Code
IW
IW+
Description
100-214-251 IWoper.book Page 104 Friday, June 16, 2017 4:12 PM
Содержание Branson 2000 Series
Страница 9: ...viii 100 214 251 REV 05 100 214 251 IWoper book Page viii Friday June 16 2017 4 12 PM ...
Страница 47: ...38 100 214 251 REV 05 100 214 251 IWoper book Page 38 Friday June 16 2017 4 12 PM ...
Страница 83: ...74 100 214 251 REV 05 100 214 251 IWoper book Page 74 Friday June 16 2017 4 12 PM ...
Страница 89: ...80 100 214 251 REV 05 100 214 251 IWoper book Page 80 Friday June 16 2017 4 12 PM ...
Страница 129: ...120 100 214 251 REV 05 100 214 251 IWoper book Page 120 Friday June 16 2017 4 12 PM ...
Страница 135: ...126 100 214 251 REV 05 100 214 251 IWoper book Page 126 Friday June 16 2017 4 12 PM ...