94
100-214-251 REV. 05
6.2.4.2 Recalling modified parameter values
When you select a parameter to modify, its value is stored temporarily in an internal
register. If, after pressing an UP/DOWN switch, you wish to return to the value you
selected initially (before pressing an UP/DOWN switch), simply press the parameter key
once more and the original value will be restored from the internal register. This option is
not available for Weld Time, or Absolute or Collapse distance values.
6.2.4.3 Recalling cold start parameter values
If you wish to return to the cold start (factory-set) parameters: as the welder is powered,
immediately after activating the welder, simultaneously press and hold the FAST UP and
the FAST DOWN switches. Hold until the welder displays “coldstrt” (IW+) or “rdy” (IW),
until the mode is changed or until the welder is recycled.
NOTICE
If a parameter can be disabled, the cold start operation will disable it. If a parameter
cannot be disabled, the cold start operation will set the parameter to its minimum
value. You can recall cold start parameters even if the display is locked.
100-214-251 IWoper.book Page 94 Friday, June 16, 2017 4:12 PM
Содержание Branson 2000 Series
Страница 9: ...viii 100 214 251 REV 05 100 214 251 IWoper book Page viii Friday June 16 2017 4 12 PM ...
Страница 47: ...38 100 214 251 REV 05 100 214 251 IWoper book Page 38 Friday June 16 2017 4 12 PM ...
Страница 83: ...74 100 214 251 REV 05 100 214 251 IWoper book Page 74 Friday June 16 2017 4 12 PM ...
Страница 89: ...80 100 214 251 REV 05 100 214 251 IWoper book Page 80 Friday June 16 2017 4 12 PM ...
Страница 129: ...120 100 214 251 REV 05 100 214 251 IWoper book Page 120 Friday June 16 2017 4 12 PM ...
Страница 135: ...126 100 214 251 REV 05 100 214 251 IWoper book Page 126 Friday June 16 2017 4 12 PM ...