7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF890
3. Ceiling Fan Assembly
(continued)
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
HAIRPIN
CLIP
MOTOR
COUPLING
SETSCREW (2)
CLEVIS PIN
DOWNROD
Figure 7
COUPLER COVER
MOTOR HOUSING
GROMMET
Figure 8
It is critical that the clevis pin in the motor coupling is
properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.
WARNING
!
3.7
Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor leads.
Route the motor lead wires through the downrod. Align
the clevis pin holes in the downrod with the holes in the
motor coupling. Install the clevis pin and secure with the
hairpin clip (Figure 7). The clevis pin must go through
the holes in the motor coupling and the holes in the
downrod. Be sure to push the straight leg of the hairpin
clip through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around the
clevis pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on the
downrod to make sure the clevis pin is properly
installed.
3.8
While pulling up on the downrod, securely tighten the
two setscrews in the motor coupling (Figure 7).
NOTE: The setscrews must be properly installed as
described above, or fan wobble could result.
3.9
Make sure the grommet is properly installed on the
coupler cover then slide the coupler cover on the
downrod until it rests on the motor housing (Figure 8).
3.10
Place the ceiling cover over the downrod. Be sure both
the ceiling cover and the coupler cover are oriented
correctly (Figure 9).