3. Ceiling Fan Assembly
5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF621
3.1
Remove the hanger ball by loosening the setscrew in
the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the pin from the downrod,
then remove the hanger ball. Retain the pin and hanger
ball for reinstallation in Step 3.5.
DOWNROD
PIN
SETSCREW
HANGER BALL
Figure 1
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
HAIRPIN
CLIP
MOTOR
COUPLING
SETSCREW (2)
CLEVIS PIN
DOWNROD
Figure 2
COUPLING
COUPLING COVER
DOWNROD
SETSCREW (2)
GROMMET
Figure 3
It is critical that the clevis pin in the motor coupling is
properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.
WARNING
!
3.2
Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor leads.
Route the motor lead wires through the downrod. Align
the clevis pin holes in the downrod with the holes in the
motor coupling. Install the clevis pin and secure with
the hairpin clip (Figure 2). The clevis pin must go
through the holes in the motor coupling and the holes in
the downrod. Be sure to push the straight leg of the
hairpin clip through the hole near the end of the clevis
pin until the curved portion of the hairpin clip snaps
around the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working loose.
Pull on the downrod to make sure the clevis pin is
properly installed.
3.3
While pulling up on the downrod, securely tighten the
two setscrews in the motor coupling (Figure 3).
NOTE: The setscrews must be properly installed as
described above, or fan wobble could result.
3.4
Make sure the grommet is properly installed in the
coupling cover then slide the coupler cover on the
downrod until it rests on the motor housing. Place the
ceiling cover over the downrod. Be sure both the ceiling
cover and the coupler cover are oriented correctly
(Figure 3).