3. Ceiling Fan Assembly

(continued)

PARTIALLY 
ASSEMBLED FAN

SOLID
STYROFOAM
FACING OUT

6" - 8"
GAP

Figure 5

SPACER ATTACHMENT
SCREW

SHIPPING
SPACER

Figure 6

3.7

Turn fan motor assembly upside down in preparation
for mounting fan blades. Position the top and bottom
halves of the styrofoam packaging on end, with solid
styrofoam facing outward. Set side-by-side on the floor
with a six to eight-inch gap between the halves (Figure
5). Carefully place the partially assembled ceiling fan
on the styrofoam halves, with the hanger ball/downrod
assembly positioned in the gap and the fan motor
assembly resting on top of the styrofoam ends.

3.8

Remove the shipping spacers and the spacer
attachment screws from the motor before installation of
blade assemblies. Discard the spacers and spacer
screws (Figure 6).

CEILING
COVER

PIN

DOWNROD

HANGER BALL

SETSCREW

Figure 4

3.5

Reinstall the hanger ball (Figure 4) on the downrod as
follows. Route the motor leads through the downrod.
Position the pin through the two holes in the downrod
and align the ball so the pin is captured in the groove in
the top of the hanger ball. Pull the hanger ball up tight
against the pin and securely tighten the setscrew in the
hanger ball. A loose setscrew could create fan wobble.

3.6

The fan comes with blue, black and white leads that are
80-inches long. Before installing the fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and strip
back insulation 1/2-inch from end of leads.

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened. Failure
to verify that the pin and setscrew are properly
installed could result in the fan falling.

WARNING

!

Содержание BATALIE BREEZE CF621SW00

Страница 1: ... 52 Wet Location Ceiling Fan Owner s Manual CF621SW00 Satin White CF621VS00 Vintage Steel Model Numbers CF621VNB00 Venetian Bronze Net Weight 26 5 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ...

Страница 2: ...al wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson...

Страница 3: ...utlet for replacement before proceeding 1 2 Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly 1 3 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly PACKAGE CONTENTS 2...

Страница 4: ... risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid ...

Страница 5: ...80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin u...

Страница 6: ...ies Discard the spacers and spacer screws Figure 6 CEILING COVER PIN DOWNROD HANGER BALL SETSCREW Figure 4 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin ...

Страница 7: ...with fan Figure 7 3 12 Remove one 8 32 x 8mm pan head screw from the lower housing adapter plate reserve for later use Loosen the other two screws to assemble the lower housing to the lower housing adapter plate Figure 9 3 13 Position the lower housing onto the fan motor assembly aligning each of the the three holes Rotate the lower housing to engage the two loosened screws in the two key hole slo...

Страница 8: ... of the switch housing assembly to the lower housing Figure 11 3 16 Position the switch housing assembly onto the lower housing aligning each of the the three holes Replace the three 8 32 x 8mm flat head screw removed previously and tighten all three screws to secure the switch housing assembly to the lower housing Figure 11 3 Ceiling Fan Assembly continued 3 14 Engage the connector of the switch ...

Страница 9: ...ws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 12 WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box...

Страница 10: ...ories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fa...

Страница 11: ...r up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 16 5 5 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 16 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your...

Страница 12: ...from the factory with the reversing switch positioned to circulate air downward 6 4 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the reversing switch located on top of the fan motor assembly to the opposite position Figure 18 and turn the fan on again The blades will turn in the opposite direction and reverse the airflow Revers...

Страница 13: ...xtension Kits see store or catalog 3 Ceiling Fan Light Kits see store or catalog 8 Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your...

Страница 14: ...ctors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to flywheel 4 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten t...

Страница 15: ...15 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF621 Notes ...

Страница 16: ...10 Repair Parts 6 1 2 3 4 5 8 7 17 18 19 21 20 10 16 15 14 12 22 23 11 13 9 16 U L Model No CF621 ...

Страница 17: ...Ball 3 Downrod 4 5 Parts Bag Containing 764208 1 764208 764208 4 Pin Clevis 1 5 Clip Hairpin 1 6 Threaded Stud 8 32 x 1 1 4 2 7 Lockwasher External Tooth 8 2 8 Knurled Knob 8 32 2 9 Screw WasherHead 10 24x12mm 21 10 Flat Washer 16mm 21 11 Screw Pan Head 8 32 x 8mm 1 12 Screw Flat Head 8 32 x 8mm 1 13 Screw Pan Head 1 4 20 x 14mm with Lockwasher 1 14 Pendant with Pull Chain and Coupling 1 15 Wire C...

Страница 18: ...18 U L Model No CF621 Notes ...

Страница 19: ... can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Servi...

Страница 20: ... Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74770000 Form No BP7477 Revision 131113 U L Model No CF621 Printed in China 11 13 ...

Отзывы: